Impact of Ophthalmic Viscosurgical Devices in Cataract Surgery

Author:

Malvankar-Mehta Monali S.12ORCID,Fu Angel3,Subramanian Yasoda4,Hutnik Cindy1

Affiliation:

1. Department of Ophthalmology, Schulich School of Medicine and Dentistry, The University of Western Ontario, London, ON, Canada

2. Department of Epidemiology and Biostatistics, Schulich School of Medicine and Dentistry, The University of Western Ontario, London, ON, Canada

3. Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada

4. Royal College of Surgeons in Ireland, Dublin, Ireland

Abstract

Background. Ophthalmic viscoelastic devices (OVDs) used during small-incision cataract surgery have numerous advantages. However, OVDs have longer retention time in an eye after surgery resulting in intraocular pressure (IOP) spikes. The purpose of this study is to analyze and quantify the effect of various OVDs on both IOP and best corrected visual acuity (BCVA) by systematically reviewing the literature and performing meta-analysis. Methods. Numerous databases from January 1, 1985, to present were systematically searched. Thirty-six (3893 subjects) of 3313 studies identified were included for analysis. Standardized mean difference (SMD) was computed, and meta-analysis was performed. Results. A total of 3313 records were retrieved including 1114 from database search and 2199 from grey literature search. Significant increase in postoperative IOP in 1-day follow-up with Healon (SMD = 0.37, CI: [0.07, 0.67]), Viscoat (SMD = 0.29, CI: [0.13, 0.45]), Provisc (SMD = 0.46, CI: [0.17, 0.76]), and Soft Shell (SMD = 0.58, CI: [0.30, 0.86]) was computed. On the other hand, results implied a nonsignificant increase in postoperative IOP with Healon GV (SMD = 0.07, CI: [−0.28, 0.41]), Healon5 (SMD = 0.15, CI: [−0.33, 0.64]), 2% HPMC (SMD = 0.32, CI: [−0.0, 0.64]), and OcuCoat (SMD = 0.26, CI: [−0.37, 0.9]). Additionally, a nonsignificant reduction in postoperative IOP was inferred with Viscoat + Provisc (SMD = −0.28, CI: [−2.23, 1.68]). Conclusion. Improvement in IOP was shown with Viscoat + Provisc. Additionally, IOP nonsignificant upsurge was observed with Healon GV, Healon5, 2% HPMC, and OcuCoat compared to significant upsurge with Healon, Viscoat, and Soft Shell.

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3