Evaluation of 3D-CEUS in the Recurrence of Liver Cancer after Radiofrequency Ablation

Author:

Bai Lianjie1,Wang Xinping2,Shi Shenglong1,Gao Jian3,Li Xing1,Wang Ying1,Jiang Maitao4,Zheng Chunlei5,Liu Huilin1ORCID

Affiliation:

1. Department of Ultrasound, The Second Hospital Affiliated with Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

2. Department of Neurology, The Third Hospital Affiliated with Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

3. Department of Ultrasound, Infectious Diseases Hospital, Qiqihar 161000, Heilongjiang, China

4. Department of Ultrasound, The First Hospital Affiliated with Harbin Medical University, Qiqihar 150001, Heilongjiang, China

5. Department of Oncology Surgery, The Second Hospital Affiliated with Qiqihar Medical University, Qiqihar 161000, Heilongjiang, China

Abstract

Background. Radiofrequency ablation (RFA) has the similar curative effects to surgery, but RFA will lead to higher postoperative local recurrence rate. 3D-CEUS is a minimally invasive examination method, which is used to analyze the sensitivity to postoperative recurrence in this study. Methods. The clinical data of 60 patients with liver cancer admitted to our hospital (February 2018-February 2020) were retrospectively analyzed. All patients were treated with RFA and were followed up with 3D-CEUS, MRI, and enhanced CT examination after surgery. The ROC curve was used to analyze the differences of different examination methods in judging postoperative recurrence. Results. For the 60 patients, 52 patients (86.7%) had a single lesion and 8 patients (13.3%) had multiple lesions, with a total of 72 lesions. After RFA, 56 lesions (77.8%) were completely inactivated and 16 lesions (22.2%) remained. Totally inactivated lesions were detected as follows: 51 (91.1%) by 3D-CEUS, 42 (75.0%) by MRI, and 50 (89.3%) by enhanced CT. During a 2-year follow-up, a total of 26 recurrent lesions were detected, 24 (92.3%) by 3D-CEUS, 12 (46.2%) by MRI, and 25 (96.2%) by enhanced CT, indicating that the sensitivity of 3D-CEUS and enhanced CT was obviously higher than that of MRI ( P < 0.001 ), without conspicuous difference between sensitivity of 3D-CEUS and enhanced CT ( P > 0.05 ). Conclusion. As a new imaging examination method based on artificial intelligence, 3D-CEUS has a high sensitivity in patients with liver cancer who underwent RFA, which can effectively judge the recurrence after surgery and should be widely used in practice.

Funder

Heilongjiang Province Medical and Health Scientific Research Project

Publisher

Hindawi Limited

Subject

Health Informatics,Biomedical Engineering,Surgery,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3