A New Reference Plasmid “pGMT27” Provides an Efficient Transgenic Detection Method for Flue-Cured Tobacco

Author:

Yu Jing1,Zhang Xiaolian1,Adil Muhammad Faheem2ORCID,Lei Bo1,Jia Mengao1,Zhao Huina1,Yu Shizhou1,Liu Jiemin3,Guo Yushuang1ORCID,Shamsi Imran Haider2ORCID

Affiliation:

1. Guizhou Academy of Tobacco Science CNTC, Tobacco Molecular Genetics Key Laboratory of China Tobacco, Guiyang 550081, Guizhou, China

2. Department of Agronomy, College of Agriculture and Biotechnology, Key Laboratory of Crop Germplasm Resource, Zhejiang University, Hangzhou 310058, China

3. Guizhou Provincial People’s Hospital, Guiyang 550002, Guizhou, China

Abstract

Owing to the economic value of its foliage, tobacco (Nicotiana tabacum) is cultivated all across the world. For the detection of genetically modified (GM) tobacco, there is a lack of universal standard material which ultimately limits the detection methods because the accuracy and comparability of the results cannot be ensured. Here, we prepared a reference plasmid “pGMT27” for the detection of GM tobacco, which was 18,296 bp in length harboring two of the tobacco endogenous and seven exogenous genes. By using qualitative PCR test for the nine genes, 10 copies were used for plasmid sensitivity. In the quantitative real-time PCR (qPCR) assays with pGMT27 as a calibrator, the reaction efficiencies for P-35S and NR were 101.427% and 98.036%, respectively, whereas the limit of detection (LOD) and limit of quantification (LOQ) were 5 copies and 10 copies per reaction. For standard deviation (SD) and relative standard deviation (RSD) of the Ct values, the repeatability values were from 0.04 to 0.42 and from 0.18% to 1.29%, respectively; and the reproducibility values were from 0.04 to 0.39 and from 0.18% to 1.14%, respectively. For the unknown sample test, the average conversion factor (Cf) was 0.39, and the accuracy bias was from −15.55% to 1.93%; for precision, the SD values ranged from 0.02 to 0.62, while RSD values were from 1.34% to 10.6%. We concluded that using the pGMT27 plasmid as a calibrator provided a highly efficient transgenic detection method for flue-cured tobacco.

Funder

China National Tobacco Corporation

Publisher

Hindawi Limited

Subject

Safety, Risk, Reliability and Quality,Food Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3