Finite Element Analysis of the Effect of Tightening Torque on the Connection Stability of a Two-Piece Zirconia Implant System

Author:

Choi Hyunsuk1ORCID,Hong Min-Ho2ORCID

Affiliation:

1. Department of Dentistry and Prosthodontics, Daegu Catholic University School of Medicine, 33 Duryugongwon-ro 17-gil, Nam-gu, Daegu 42472, Republic of Korea

2. Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, 57 Oryundae-ro, Geumjeong-gu, Busan 46252, Republic of Korea

Abstract

Purpose. Loosening and fracture of abutment screws are one of the most common complications in implant-retained fixed prostheses. Thus, applying the proper tightening torque to the abutment screw is important for preventing the loosening effect of the abutment screw and ensuring the stability of the implant fixture-abutment connection. Therefore, in this study, we aimed to investigate the effect of the tightening torque of the abutment screw on the stability of the fixture-abutment connection in a two-piece zirconia implant system using finite element analysis (FEA). Materials and Methods. The two-piece zirconia implant structures used in this study were designed using the CATIA program. The abutment screws with tightening torques of 25 (TT-25), 35 (TT-35), and 45 (TT-45) N·cm were assumed to fix the abutment and fixture. Vertical (200 N) and oblique (100 N) loads were applied to the finite element model generated for FEA simulation, and the stress levels and distributions were investigated. Results. The TT-45 group exhibited the highest von Mises stress in the abutment and fixture, followed by the TT-35 and TT-25 groups. The von Mises and minimal principal stresses of the abutment screw were also highest in the TT-45 group, followed by the TT-35 and TT-25 groups. In all three groups, the area with the highest stress concentration was located at the point of contact with the bottom of the screw head. Furthermore, the TT-25 group showed the highest safety factor value. The TT-35 group showed a safety factor value similar to the safe minimum standard, while the TT-45 group showed a lower safety factor value. Conclusion. When a torque of 35 N cm was applied to the two-piece zirconia implant system, it showed a maximum stress value close to 660 MPa (75% of the yield strength of the Ti-6Al-4V alloy), which is the optimal preload recommended for abutment screws.

Funder

Ministry of Science and ICT, South Korea

Publisher

Hindawi Limited

Subject

General Engineering,General Materials Science

Reference42 articles.

1. Implant biomaterials: A comprehensive review

2. Clinical performance of two-piece zirconia implants in the posterior mandible and maxilla: a prospective cohort study over 2 years

3. Current Findings Regarding Zirconia Implants

4. State of the art of zirconia for dental applications

5. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants;A. Çaglar;The International Journal of Oral & Maxillofacial Implants,2011

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司