Statistical Validation for Clinical Measures: Repeatability and Agreement of Kinect™-Based Software

Author:

Lopez Natalia1ORCID,Perez Elisa1ORCID,Tello Emanuel1,Rodrigo Alejandro1,Valentinuzzi Max E.12

Affiliation:

1. Gabinete de Tecnología Médica, Facultad de Ingeniería, Universidad Nacional de San Juan, CONICET, San Juan, Argentina

2. Instituto Superior de Investigaciones Biológicas, CONICET, Tucumán, Argentina

Abstract

Background. The rehabilitation process is a fundamental stage for recovery of people’s capabilities. However, the evaluation of the process is performed by physiatrists and medical doctors, mostly based on their observations, that is, a subjective appreciation of the patient’s evolution. This paper proposes a tracking platform of the movement made by an individual’s upper limb using Kinect sensor(s) to be applied for the patient during the rehabilitation process. The main contribution is the development of quantifying software and the statistical validation of its performance, repeatability, and clinical use in the rehabilitation process. Methods. The software determines joint angles and upper limb trajectories for the construction of a specific rehabilitation protocol and quantifies the treatment evolution. In turn, the information is presented via a graphical interface that allows the recording, storage, and report of the patient’s data. For clinical purposes, the software information is statistically validated with three different methodologies, comparing the measures with a goniometer in terms of agreement and repeatability. Results. The agreement of joint angles measured with the proposed software and goniometer is evaluated with Bland-Altman plots; all measurements fell well within the limits of agreement, meaning interchangeability of both techniques. Additionally, the results of Bland-Altman analysis of repeatability show 95% confidence. Finally, the physiotherapists’ qualitative assessment shows encouraging results for the clinical use. Conclusion. The main conclusion is that the software is capable of offering a clinical history of the patient and is useful for quantification of the rehabilitation success. The simplicity, low cost, and visualization possibilities enhance the use of the software Kinect for rehabilitation and other applications, and the expert’s opinion endorses the choice of our approach for clinical practice. Comparison of the new measurement technique with established goniometric methods determines that the proposed software agrees sufficiently to be used interchangeably.

Funder

Universidad Nacional de San Juan

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3