Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage

Author:

Oesterlein Tobias1ORCID,Frisch Daniel1,Loewe Axel1ORCID,Seemann Gunnar23,Schmitt Claus4,Dössel Olaf1,Luik Armin4

Affiliation:

1. Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany

2. Institute for Experimental Cardiovascular Medicine, University Heart Center Freiburg ·​ Bad Krozingen, Medical Center, University of Freiburg, 79106 Freiburg, Germany

3. Faculty of Medicine, University of Freiburg, 79106 Freiburg, Germany

4. Städtisches Klinikum Karlsruhe, 76133 Karlsruhe, Germany

Abstract

Whole-chamber mapping using a 64-pole basket catheter (BC) has become a featured approach for the analysis of excitation patterns during atrial fibrillation. A flexible catheter design avoids perforation but may lead to spline bunching and influence coverage. We aim to quantify the catheter deformation and endocardial coverage in clinical situations and study the effect of catheter size and electrode arrangement using an in silico basket model. Atrial coverage and spline separation were evaluated quantitatively in an ensemble of clinical measurements. A computational model of the BC was implemented including an algorithm to adapt its shape to the atrial anatomy. Two clinically relevant mapping positions in each atrium were assessed in both clinical and simulated data. The simulation environment allowed varying both BC size and electrode arrangement. Results showed that interspline distances of more than 20 mm are common, leading to a coverage of less than 50% of the left atrial (LA) surface. In an ideal in silico scenario with variable catheter designs, a maximum coverage of 65% could be reached. As spline bunching and insufficient coverage can hardly be avoided, this has to be taken into account for interpretation of excitation patterns and development of new panoramic mapping techniques.

Funder

Deutsche Forschungsgemeinschaft

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献