Transcatheter Closure of Perimembranous Ventricular Septal Defect with Aneurysm: Radiologic Characteristic and Interventional Strategy

Author:

Guo Weibing1ORCID,Li Yifan2ORCID,Yu Jinjin2ORCID,Li Junjie2ORCID,Sun Ling2ORCID,Shi Jijun2ORCID,Wang Shushui2ORCID,Chen Hong3ORCID,Zhang Zhiwei2ORCID

Affiliation:

1. Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangdong, China

2. Department of Pediatric Cardiology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangdong Cardiovascular Institute, Guangdong, China

3. Shantou University Medical College, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangdong, China

Abstract

Objectives. We aimed to explore the radiologic characteristics and interventional strategies for perimembranous ventricular septal defect (pmVSD) with aneurysm. Methods. 257 patients who underwent transcatheter closure of pmVSD with aneurysm were included in our study. We retrospectively reviewed the left ventricular opening of the aneurysm (a), diameter of the midsegment of the aneurysm (b), and diameter of the right ventricular opening of the aneurysm (c). If there were multiple defects within the aneurysm, the largest defect was denoted as c1 and so forth. We developed a novel VSD classification method in which pmVSD with aneurysm was classified into three types (A, B, and C). When a >b ≥ c, it was classified as type A, when b > a ≥ c, it was type B, and when c > a ≥ b, it was type C; c/c1 described the relationship among defects. Results. All of the 257 cases of pmVSD with aneurysm were defined using left ventriculography: type A, 60, type B, 58, and type C, 139. Transcatheter closure was attempted in 244 patients and succeeded in 227 cases (success rate was 93.0%; 227/244). Forty symmetric VSD occluders and 13 asymmetric VSD occluders were used for type A aneurysm occlusion; 31 symmetric VSD occluders, 19 asymmetric VSD occluders, and one Amplatzer duct occluder II (ADOII) were used for type B; 59 VSD symmetric occluders, 59 asymmetric VSD occluders, three eccentric VSD occluders, and two ADOII were used for type C. Within 24 hours after procedure, 2.2% patients had postprocedural residual shunt, and 2.2% experienced malignant arrhythmia (including type II second-degree AVB, cAVB, and CLBBB). Two hundred and twelve patients completed follow-up (93%, 212/227). No new severe complications were reported during follow-up, except in one patient who underwent surgery (removal of the device, VSD repair, and tricuspid valvuloplasty) due to severe postprocedural tricuspid regurgitation. Conclusions. It is safe and effective to apply this method for the classification of pmVSD with aneurysm and its interventional strategy.

Funder

National Key R&D Program of China

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3