Factors Associated with the Technical Success of Bilateral Endoscopic Metallic Stenting with Partial Stent-In-Stent Placement in Patients with Malignant Hilar Biliary Obstruction

Author:

Fujita Toshihiro1,Hashimoto Shinichi1ORCID,Tanoue Shiroh1,Tsuneyoshi Kengo1,Nakamura Yoshitaka1,Hinokuchi Makoto1,Iwaya Hiromichi1,Arima Shiho1,Iwashita Yuji1,Sasaki Fumisato1,Taguchi Hiroki1,Kanmura Shuji1,Ido Akio1

Affiliation:

1. Digestive and Lifestyle Diseases, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima 890-8520, Japan

Abstract

Background. Bilateral biliary drainage decreases the risk of cholangitis, but bilateral endoscopic metallic stenting is technically challenging. Aim. We retrospectively evaluated the factors associated with successful bilateral self-expanding metal stent (SEMS) placement using the partial stent-in-stent (PSIS) method for malignant hilar biliary obstruction and also assessed the safety and efficacy of this technique. Methods. From April 2010 to February 2016, 47 consecutive patients (mean age, 73.0±8.6 years; 32 males and 15 females) underwent PSIS placement for malignant hilar biliary obstruction in our hospital. The technical success of PSIS, clinical response, and complications were investigated. Factors associated with the technical success of PSIS were assessed. Using a propensity score-matched analysis, we compared the procedure time, clinical response, complications, stent patency, and survival time in 17 matched patients treated with bilateral SEMS placement using a SEMS delivery system of <6.0 or ≥6.0 Fr. Results. The technical success rate was 77%. The clinical response rate was 91%, and the complication rate was 26%. Regarding complications, pancreatitis occurred in 5 patients (11%), cholangitis in 6 (13%), and cholecystitis in 1 (2%). A multiple logistic regression analysis identified the use of a SEMS with a delivery system<6.0Fr as a factor associated with technical success (P=0.033; odds ratio, 10.769; 95% confidence interval, 1.205-96.212). In the 17 matched patients assigned according to the SEMS delivery system size, the procedure time was significantly shorter in those with a delivery system size<6.0Fr than in those with ≥6.0 Fr (P<0.01). There were no significant differences in the clinical response, complication rate, stent patency, or survival time between the two groups. Conclusion. Using a delivery system<6.0Fr in size helped improve the technical success and reduced the procedure time for the placement of a SEMS by the PSIS method.

Publisher

Hindawi Limited

Subject

Gastroenterology,Hepatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3