Effects of Diode, CO2, Er : YAG, and Er and Cr : YSGG on Titanium Implant Surfaces by Scanning Electron Microscopy

Author:

Moeintaghavi Amir1ORCID,Bagheri Hossein2,Pour Mahdie Yavari3,Shafiei Shervin4,Moslemi Hamidreza4,Abbasi Kamyar5ORCID,Nobar Behrad Rahbani6,Mehdizadeh Amirreza3,Ahrari Farzaneh1,Alam Mostafa4ORCID

Affiliation:

1. Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran

2. Dental Materials Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran

3. Department of Oral and Maxillofacial Radiology, School of Dentistry, Islamic Azad University, Tehran, Iran

4. Department of Oral and Maxillofacial Surgery, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran

5. Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran

6. Private Practice, Tehran, Iran

Abstract

This study aimed to determine the effects of various lasers on dental implants’ surface characteristics. Nine explanted dental implants were included. Two implants were randomly allocated to four intervention groups, namely, diode (2 W, 810 nm, 10 s), CO2 (2 W, 10600 nm, 10 s), Er : YAG (200 mJ/20 Hz, 2940 nm, 10 s), and Er, Cr : YSGG (200 mJ/20 Hz, 2780 nm, 10 s) groups and one control group. After laser irradiation, all implants were imaged with scanning electron microscopy. Qualitative changes on the surface of implants were evaluated. Quantitative surface changes at the threads and between the threads were assessed by software using depression and prominence plots. The paired t-test was used for statistical analysis. Diode laser irradiation showed the least surface changes while the Er : YAG group showed the greatest surface changes. Furthermore, CO2 and Er : YAG laser irradiation significantly altered the mean profile area at the threads ( p < 0.05 ), while CO2 and Er, Cr : YSGG laser irradiation significantly altered the mean profile area between the threads ( p < 0.05 ). Diode laser irradiation does not alter the implant surface characteristics. However, the use of CO2, Er : YAG, and Er, Cr : YSGG lasers on titanium implant surfaces is discouraged as they damage the titanium implant surfaces.

Publisher

Hindawi Limited

Subject

General Engineering,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3