Analytical Validation of MINI-PET as Point-of-Care for Erythrocyte Sedimentation Rate Measure in Horses

Author:

Pieroni Carolina1ORCID,Grassi Andrea23ORCID,Pantoli Marianna2ORCID,Berretti Mirko1ORCID,Messina Stefano4ORCID,Giovannini Chiara5ORCID,Lubas George6ORCID,Diamanti Daniela1ORCID

Affiliation:

1. DIESSE- Diagnostica Senese S.p.A. Società Benefit, Strada dei Laghi, 35-39, Monteriggioni, Siena, Italy

2. I-Vet Diagnostica Veterinaria, Via Ettore Majorana, 10, Flero, Brescia, Italy

3. Istituto Zooprofilattico Sperimentale della Lombardia e dell’Emilia Romagna, Sede Territoriale di Pavia, Str. Privata Campeggi, 59, Pavia, Italy

4. Azienda Ospedaliera Universitaria Senese, V.le Mario Bracci, 11, Siena, Italy

5. Il Ceppo Equine Hospital, Strada Monteresi 3, Monteriggioni, Siena, Italy

6. Clinica Veterinaria Colombo, VetPartners Italia, V.le Colombo 153, Lido di Camaiore, Lucca, Italy

Abstract

The erythrocyte sedimentation rate (ESR) is a widely used diagnostic assay in human medicine but nowadays poorly applied in veterinary medicine. This test measures the speed (millimeters per hour) at which red blood cells settle in a whole anticoagulated blood tube. In human medicine, high ESR values are associated with various disorders, including infections, rheumatoid arthritis, oncologic diseases, and other inflammatory conditions. The ESR can also be influenced by some factors such as age and gender. In veterinary medicine, the ESR with the Westergren manual method was almost forgotten over the years due to blood consumption and long turn-around time. The instrument MINI-PET, using a modified Westergren method, does not require blood consumption or release waste product and recently has been applied in canine medicine. The aims of the study in the horse were as follows: to establish the appropriate time to read the ESR with the Westergren reference method; to compare the MINI-PET ESR results with the reference technique; to assess the ESR reference intervals with MINI-PET; and to establish the ESR stability from collection at different time points by MINI-PET. Using 150 horses, we established 60 minutes as the appropriate time for ESR reading with the Westergren method. Moreover, ESR results obtained in 8 minutes with MINI-PET showed a good correlation with the Westergren ESR. Reference intervals (RIs) with MINI-PET were established in mm/h for the healthy horses (geldings 18.6–100.1; stallions, 13.8–55.7; and mares 1–73.7) according to the American Society of Veterinary Clinical Pathology guidelines. In addition, the ESR stability from the blood collection time was evaluated in the MINI-PET on 15 horses: at room temperature, ESR is stable up to 8 hours and at 4°C up to 24 hours. In conclusion, MINI-PET represents a rapid and reliable tool for measuring ESR in horses, offering a valid option to replace the traditional manual technique.

Publisher

Hindawi Limited

Subject

General Veterinary

Reference29 articles.

1. Clinical utility of the erythrocyte sedimentation rate;M. L. Brigden;American Family Physician,1999

2. Erythrocyte aggregation: Basic aspects and clinical importance

3. Erythrocyte sedimentation rate;K. Tishkowski,2023

4. (Expert Panel on Blood Rheology) “ICSH recommendations for measurement of erythrocyte sedimentation rate”;International Council for standardization in Haematology;Journal of Clinical Pathology,1993

5. The erythrocyte sedimentation rate: old and new clinical application;C. Saadeh;Southern Medical Journal,1998

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3