An Effective Flocculation Method to the Kaolin Wastewater Treatment by a Cationic Polyacrylamide (CPAM): Preparation, Characterization, and Flocculation Performance

Author:

Zakaria Djibrine Badradine12ORCID,Zheng Huaili12ORCID,Wang Moxi12,Liu Shuang12,Tang Xiaomin123ORCID,Khan Sarfaraz12,Jimenéz Andrea Navarro12,Feng Li12ORCID

Affiliation:

1. Key Laboratory of the Three Gorges Reservoir Region’s Eco-Environment, Ministry of Education, Chongqing University, Chongqing 400045, China

2. National Centre for International Research of Low-carbon and Green Buildings, Chongqing University, Chongqing 400045, China

3. Chongqing Key Laboratory of Catalysis and Environmental New Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 400067, China

Abstract

P(AM-DMC) (PAD) was synthesized by ultraviolet- (UV-) initiated copolymerization with methacryloxyethyl trimethyl ammonium chloride (DMC) and acrylamide (AM) as the monomers and initiator 2,2-azobis [2-(2-imidazolin-2-yl) propane] dihydrochloride (VA-044) as the photoinitiator. Parameters that affect the molecular weight were reviewed by using the single-factor approach. The results showed that the molecular weight (MW) of PAD could come to 7.88 × 106 Da with the optimum polymerization conditions as follows: monomer concentration of 30%, monomer mass ratio m(AM) : m(DMC) of 3 : 1, initiator concentration of 0.6‰, illumination time of 80 min, solution pH value of 4.5, and incident light intensity of 1000 μW cm−2. The PAD was represented by several instruments. The results of FTIR and 1H NMR showed that PAD was indeed polymerized by AM and DMC. The results of TGA showed that PAD was very stable at room temperature while the result of SEM revealed that PAD had a porous structure and rough surface. For PAD used as flocculant in kaolin wastewater treatment, the results confirmed that, at optimal conditions, the turbidity and the floc size d50 could reach to 5.9 NTU and 565.936 μm, respectively, at the optimal conditions (pH = 7.0 and dosage = 2 mg l−1). Kaolin wastewater flocculation test outcome reveals that the PAD with high cationic degree and intrinsic viscosity could boost the charge neutralization and bridging capability. Consequently, the result is an excellent flocculation performance of treating kaolin wastewater.

Funder

Chongqing Postdoctoral Science Foundation

Publisher

Hindawi Limited

Subject

Polymers and Plastics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3