Comparison of the Stability of Two Intraocular Lenses in Primary Angle-Closure Glaucoma after Phacoemulsification

Author:

Zhang Chang1,Zhang Meng2ORCID,Zhang Bing1ORCID,Wang Shanhong1ORCID,Wang Yuhong3ORCID

Affiliation:

1. Eye Department, Tongde Hospital of Zhejiang Province, No. 234 Gucui Road, Hangzhou, Zhejiang Province, China

2. Glaucoma Department, Eye Hospital of Zhejiang Province, No. 270 West College Road, Lucheng District, Wenzhou, Zhejiang Province, China

3. Xiamen University Affiliated Xiamen Eye Center, 336 Xiahe Road, Siming District, Xiamen, Fujian Province, China

Abstract

Objective. To observe the stability of intraocular lenses (IOLs) in primary angle-closure glaucoma by ultralong scan depth spectral-domain optical coherence tomography (UL-OCT) after phacoemulsification. Methods. A prospective, randomized study. 73 patients (82 eyes) with primary closed-angle glaucoma and age-related cataract were included in the study. 42 eyes were implanted with ZCB00, while 40 eyes were implanted with Softec HD after phacoemulsification. The tilt, decentration, and space between IOL and posterior capsule (IOL-PC space) were analyzed using UL-OCT at 1 week, 1 month, and 3 months after surgery. The intergroup difference was compared with the paired t-test. Result. The difference of decentration and tilt was not statistically significant (both P > 0.05 ) both in the horizontal and vertical positions at 1 week, 1 month, and 3 months postoperatively. The horizontal IOL-PC space is 0.111 ± 0.091 mm2, 0.044 ± 0.066 mm2, and 0.055 ± 0.055 mm2 in the Softec HD group and 0.458 ± 0.488 mm2, 0.497 ± 0.363 mm2, and 0.492 ± 0.441 mm2 in the ZCB00 group. The vertical IOL-PC space is 0.102 ± 0.061 mm2, 0.037 ± 0.052 mm2, and 0.053 ± 0.079 mm2 in the Softec HD group and 0.692 ± 0.815 mm2, 0.510 ± 0.415 mm2, and 0.691 ± 0.635 mm2 in the ZCB00 group. The difference was statistically significant ( P < 0.05 ) both in the horizontal and vertical positions except for the first week on the horizon. The Softec HD group is smaller than the ZCB00 group. Conclusion. There is no difference in the stability of the IOL although the IOL-PC space is different. The thickness of IOL may affect the IOL-PC space.

Funder

Key Laboratory of Myopia, Health Commission, Fudan University

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3