Volume Fluctuations in Active and Nonactive Transtibial Prosthetics Users

Author:

Hamzah Nur Afiqah1,Razak Nasrul Anuar Abd1ORCID,Karim Mohd Sayuti Ab2,Salleh Siti Zuliana2

Affiliation:

1. Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia

2. Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia

Abstract

This study aims to evaluate the validity and reliability of the Biosculptor’s Bioscanner system in capturing transtibial residual limb volume fluctuations in active and nonactive amputees during walking activity. Residual limb volume was obtained by measuring the limb circumference after amputees walked for 5 to 25 minutes for five consecutive days. The comparison of mean circumference between Bioscanner and manual measurements (i.e., tape measure) showed that the Bioscanner gave a higher estimation of circumference for the different amputees. Short-term changes in girth and volume due to an activity such as walking do not fluctuate uniformly. The results reflected as such as nonconsistence circumference change identified at different locations of the circumference profiles. Both amputees experienced a significant increase in circumference at the distal end of the limbs after 5 minutes of walking (7.35% change in nonactive and 8.83% in active amputees), and the measurement decreased as amputees walked longer. At 4-8 cm below the mid-patella tendon (pressure tolerant areas), both amputees experienced minor changes in the size of their circumference. The residual limb volume calculation resulted in the percentage difference between the two methods ranging from 2.4% to 9.3%. Pearson coefficient correlation obtained showed a high correlation between the two techniques, ranging from 0.97 to 1. The analysis of the limit of agreements showed that the majority of measurements were closed to the mean, suggesting that Bioscanner and manual techniques may be interchangeable and agree with one another. This study has implied that Bioscanner is comparable to the standard measurement method and may serve as an alternative tool in managing daily residual limb volume change.

Funder

Ministry of Health (MOH) Malaysia

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3