Identification and Determination of Impurities in a New Therapeutic Agent for Fatty Liver Disease

Author:

Shao Huihui1ORCID,Feng Jing1,Zhang Hanyilan1ORCID,Zhang Yuanyuan1,Qin Tong1ORCID,Hu Yuhua1,Zhang Wenxuan1ORCID,Wang Tiesong2,Wu Song1ORCID,Yang Qingyun1ORCID

Affiliation:

1. State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China

2. NMPA Key Laboratory for Research and Evaluation of Generic Drugs, Beijing Institute for Drug Control, Beijing 102206, China

Abstract

Methyl 7,7′-dimethoxy-5′-(morpholinomethyl)-[4,4′-bibenzo[d][1,3] dioxole]-5-carboxylate methanesulfonate (IMM) is an innovative drug for the treatment of nonalcoholic fatty liver disease (NAFLD) owing to its high efficacy and low toxicity. In this study, five minor impurities (I, II, III, IV, and V) were identified and analyzed using spectroscopic evidence, chemical synthetic methods, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The impurities included hydrolysates and oxidation by-products extracted from both the drug in its final formulation and during synthesis. Toxicity prediction revealed potential carcinogenicity of impurity V containing an N-oxygen fragment. A reliable and selective HPLC method for the quantitative analysis of impurities I–IV and a sensitive HPLC-MS/MS method for potential genotoxic impurity V were developed and optimized. The methods were validated based on the International Council for Harmonization guidelines. Satisfactory linearity was obtained for the analytes over the range of 0.1–2.0 μg/mL for impurities I–IV and 0.3–30.0 ng/mL for impurity V, and in all cases, the fitting correlation coefficients exceeded 0.999. The obtained limits of detection values were 0.05 ng/mL and 0.005 μg/mL for impurity V and impurities I–IV, respectively. The precision and repeatability of the methods were less than 1.08% and 8.72% for each impurity. The recovery percentages of all impurities were in the range of 91.18%–111.27%, with the relative standard deviation of less than 3.69%. The greenness assessment of the HPLC method and the HPLC-MS/MS method were evaluated by using AGREE software with a score value of 0.72 and 0.68, respectively. The recommended procedures that were accurate, specific, and ecofriendly were applied to the existing active pharmaceutical ingredients of IMM, and they generated satisfactory results.

Funder

Chinese Academy of Medical Sciences

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3