Minimally Invasive Screw Fixation of Unstable Pelvic Fractures Using the “Blunt End” Kirschner Wire Technique Assisted by 3D Printed External Template

Author:

Chen Kaifang1ORCID,Yao Sheng1,Yang Fan1,Drepaul Deepak1,Telemacque Dionne1,Zhu Fengzhao1,Zeng Lian1,Xiong Zekang1,Sun Tingfang1,Guo Xiaodong1ORCID

Affiliation:

1. Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science & Technology, Jiefang Avenue No. 1277, Wuhan, Hubei 430022, China

Abstract

Objective. This study aimed to determine the accuracy and safety of the “blunt end” Kirschner wire (KW) technique for the minimally invasive treatment of unstable pelvic fractures with the assistance of a 3D printed external template. Methods. Clinical data of 28 patients with unstable pelvic fractures between January 2016 and January 2018 were retrospectively analyzed. There were 6 cases of B1, 10 of B2, 8 of C1, and 4 of C2 fractures, all of which received surgical treatment. The “blunt end” KW technique with a 3D template was adopted for the minimally invasive placement of the iliosacral (IS) or superior ramus screws. The number of intraoperative fluoroscopies, surgical time, and complications were recorded. Postoperative reduction was assessed using the Matta criteria, and the Majeed score system was used to evaluate postoperative functional recovery. Results. The average number of fluoroscopies was 35 per patient, and the average surgical time was 85.2 min. A total of 19 S1 and 28 S2 IS screws were inserted. Eleven antegrade superior ramus screws and 4 retrograde screws were placed in 11 patients, and anterior subcutaneous internal fixation (INFIX) was used to fix the anterior pelvic ring in 17 patients. All patients were followed up for an average of 18 months. Postoperative reduction was evaluated by Matta’s criteria: excellent in 16 cases, good in 9 cases, and fair in 3 cases. The Majeed score was used in the last follow-up to evaluate functional recovery: excellent in 13 cases, good in 10 cases, fair in 4 cases, and poor in 1 case. There were no cases of operative vascular injury. Conclusion. The “blunt end” KW technique with a 3D printed external template is a safe and effective method for the placement of IS and superior ramus screws in unstable pelvic fractures with minimized surgical duration and radiation exposure.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3