Microleakage Evaluation of Two Methacrylate-Based Composites (GC Kalore and Luna SDI) in Class II Restorations: A Laboratory Study

Author:

Moradi Kooshan1ORCID,Mahmoudinezhad Sadaf Sadat1ORCID,Mapar Mehran1ORCID

Affiliation:

1. Department of Operative Dentistry, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Abstract

Objective. In recent years, dental composite resins such as tooth-colored restoration are frequently used to restore dental cavities, coronal fractures, and congenital defects. This study aimed to evaluate the microleakage of two methacrylate-based composites (GC Kalore and Luna SDI) in class II restorations. Materials and Methods. In this experimental study, a total of 18 intact human premolars previously extracted for periodontal and orthodontic reasons were randomly divided into two groups. Similar class II cavities (box only) were prepared on all teeth and restored with two different composites. In group 1, a bonding agent (Single Bond 2-SB2; 3M ESPE) and Luna SDI composite in mesial cavities and GC Kalore composite in distal cavities were used. In group 2, Single Bond 2 and GC Kalore composite in mesial cavities and Luna SDI composite in distal cavities were applied. They were then subjected to 2000 thermal cycles in a water bath between 5–55°C (dwell time: 30 seconds in every bath and transfer time: 10 seconds). Then, they were immersed in a 2% basic fuchsin dye solution for 24 hours. After rinsing with water, they were sectioned mesiodistally and evaluated for microleakage using a stereomicroscope. Results. Independent t-test (Mann–Whitney test) showed no statistically significant difference for microleakage in mesial and distal class II restorations between GC Kalore composite and Luna SDI composite ( p  = 1.000) ( p = 0.852). A total of 83.4% of the Luna SDI composite samples and 66.6% of the GC Kalore composite had a microleakage score of ≤3 in class II cavities. Conclusion. In the present study, marginal microleakage was found mainly at the gingival floor extending to 1/3 of the axial wall for the Luna SDI composite and GC Kalore composite. Furthermore, no statistically significant difference was found between the microleakage of the Class II cavities restored with Luna SDI composite and GC Kalore composite.

Publisher

Hindawi Limited

Subject

Biomedical Engineering,Biomaterials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3