Novel and Simple Ultrasonographic Methods for Estimating the Abdominal Visceral Fat Area

Author:

Asano Takeharu12ORCID,Kubota Naoto23ORCID,Koizumi Norihiro245,Itani Kazunori26,Mitake Tsuyoshi2,Yuhashi Kazuhito27,Liao Hongen248,Mitsuishi Mamoru24,Takeishi Shigemi9,Takahashi Toshiaki9,Ohnishi Shin27,Sasaki Shiro9,Sakuma Ichiro24,Kadowaki Takashi23ORCID

Affiliation:

1. Department of Gastroenterology, Saitama Medical Center, Jichi Medical University, Saitama, Japan

2. Translational Systems Biology and Medicine Initiative (TSBMI), University of Tokyo, Tokyo, Japan

3. Department of Diabetes and Metabolic Diseases, Graduate School of Medicine, University of Tokyo, Tokyo, Japan

4. Graduate School of Engineering, University of Tokyo, Tokyo, Japan

5. Graduate School of Informatics and Engineering, University of Electro-Communications (UEC), Tokyo, Japan

6. Hitachi Ltd., Tokyo, Japan

7. Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan

8. Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China

9. Institute of Rural Medicine, Hiraka General Hospital, Yokote, Akita, Japan

Abstract

Objectives.To evaluate the abdominal visceral fat area (VFA), we developed novel ultrasonographic (US) methods for estimating.Methods.100 male volunteers were recruited, and their VFA was calculated by two novel US methods, the triangle method and the ellipse method. The VFA calculated by these methods was compared with the VFA calculated by CT.Results.Both the VFA calculated by the triangle method (r=0.766,p<0.001) and the ellipse method (r=0.781,p<0.001) showed a high correlation coefficient with the VFA calculated by CT. Also, the VFA calculated by our novel methods were significantly increased in subjects with one or more metabolic risk factors than in those without any risk factors. Furthermore, the correlation coefficients obtained using the two methods were enhanced by the addition of multiple regression analysis (with the triangle method,r=0.8586,p<0.001; with the ellipse method,r=0.8642,p<0.001).Conclusions.The VFA calculated by the triangle or ellipse method showed a high correlation coefficient with the VFA calculated by CT. These US methods are easy to use, they involve no radiation exposure, and the measurements can be conducted frequently. We hope that our simple methods would be widely adopted for the evaluation of VFA.

Funder

Ministry of Education, Culture, Sports, Science and Technology of Japan

Publisher

Hindawi Limited

Subject

Endocrine and Autonomic Systems,Endocrinology,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3