Modifications of Surgical Suction Tip Geometry for Flow Optimisation: Influence on Suction-Induced Noise Pollution

Author:

Friedrich M. G.1ORCID,Tirilomis T.1ORCID,Kollmeier J. M.2,Wang Y.3,Hanekop G. G.4

Affiliation:

1. Department of Thoracic, Cardiac and Vascular Surgery, University Medical Center Göttingen, Göttingen, Germany

2. Max Planck Institute for Biophysical Chemistry, Göttingen, Germany

3. Max Planck Institute for Dynamics and Self-Organization, Göttingen, Germany

4. Department of Anaesthesiology, University Medical Center Göttingen, Göttingen, Germany

Abstract

Introduction. Suction devices for clearing the surgical field are among the most commonly used tools of every surgeon because a better view of the surgical field is essential. Forced suction may produce disturbingly loud noise, which acts as a nonnegligible stressor. Especially, in emergency situations with heavy bleeding, this loud noise has been described as an impeding factor in the medical decision-making process. In addition, there are reports of inner ear damage in patients due to suction noises during operations in the head area. These problems have not been solved yet. The purpose of this study was to analyse flow-dependent suction noise effects of different surgical suction tips. Furthermore, we developed design improvements to these devices.Methods. We compared five different geometries of suction tips using an in vitro standardised setup. Two commercially available standard suction tips were compared to three adapted new devices regarding their flow-dependent (10–2000 mL/min) noise emission (dB, weighting filter (A), distance 10 cm) and acoustic quality of resulting noises (Hamilton fast Fourier analysis) during active suction at the liquid-air boundary. Noise maps at different flow rates were created for all five suction devices, and the proportion of extracted air was measured. The geometries of the three custom-made suction tips (new models 1, 2, and 3) were designed considering the insights after determining the key characteristics of the two standard suction models.Results. The geometry of a suction device tip has significant impact on its noise emission. For the standard models, the frequency spectrum at higher flow rates significantly changes to high-frequency noise patterns (>3 kHz). A number of small side holes designed to prevent tissue adhesion lead to increased levels of high-frequency noise. Due to modifications of the tip geometry in our new models, we are able to achieve a highly significant reduction of noise level at low flow rates (new model 2 vs. standard modelsp<0.001) and also the acoustic quality improved. Additionally, we attain a highly significant reduction of secondary air intake (new model 2 vs. the other modelsp<0.001).Conclusion. Improving flow-relevant features of the geometry of suction heads is a suitable way to reduce noise emissions. Optimized suction tips are significantly quieter. This may help us to reduce noise-induced hearing damage in patients as well as stress of medical staff during surgery and should lead to quieter operation theatres overall. Furthermore, the turbulence reduction and reduced secondary air intake during the suction process are expected to result in protective effects on the collected blood and thus could improve the quality of autologous blood retransfusions. We are on the way to evaluate potential benefits.

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3