Development and Validation of an HPLC Method for Determination of Antidiabetic Drug Alogliptin Benzoate in Bulk and Tablets

Author:

Naseef Hani12ORCID,Moqadi Ramzi2ORCID,Qurt Moammal2ORCID

Affiliation:

1. Samih Darwazah Institute for Pharmaceutical Industries, Faculty of Pharmacy, Nursing and Health Professions, Birzeit University, Birzeit, State of Palestine

2. Pharmacy Department, Faculty of Pharmacy, Nursing and Health Professions, Birzeit University, Birzeit, State of Palestine

Abstract

Alogliptin benzoate, a member of dipeptidyl peptidase-4 inhibitors, is a recent drug developed by Takeda Pharmaceutical Company for the treatment of Type 2 diabetes; it potentiates the effect of incretin hormones through the inhibition of their degradation. Alogliptin can be used alone or in combination therapy. A new sensitive and rapid HPLC method was developed for the determination of alogliptin benzoate in bulk and pharmaceutical dosage forms; it was validated according to ICH and FDA guidelines. The HPLC analysis was performed on the Agilent 1200 system equipped with a Hypersil Gold Thermo Scientific C18 (250 cm × 4.6 mm) 5 µm column, with a mixture of acetonitrile and ammonium carbonate buffer in the ratio of 55 : 45 v/v as the mobile phase, at the flow rate of 1.0 mL/min. The detection was performed at the wavelength (λ) of 277, and the retention time of alogliptin benzoate was around 4 min. The total run time was 6.0 min. The calibration plot gave linear relationship over the concentration range of 85–306 µg/ml. The LOD and LOQ were 0.03 and 0.09 μg, respectively. The accuracy of the proposed method was determined by recovery studies and was found to be 100.3%. The repeatability testing for both standard and sample solutions showed that the method is precise within the acceptable limits. RSD% of the determination of precision was <2%. The results of robustness and solutions stability studies were within the acceptable limits as well. The proposed method showed excellent linearity, accuracy, precision, specificity, robustness, LOD, LOQ, and system suitability results within the acceptance criteria. In addition, the main features of the developed method are low run time and retention time around 4 min.

Funder

Hikma Pharmaceutical Company

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3