Abstract

Purpose. This US FDA investigational device exemption (IDE) study evaluated the extended use of The Spanner® Temporary Prostatic Stent in catheter-dependent men with urinary retention who were not deemed candidates for corrective surgery but demonstrated bladder contractility. Materials and Methods. The Spanner was placed for 3 cycles of 30 days in catheter-dependent men with comorbid conditions, confirmed detrusor contractility, and catheter-associated discomfort. At each visit, postvoid residual, maximum flow rate, international prostate symptom score, quality of life, and adverse events were assessed. Voiding success was defined as PVR ≤ 150 ml at all visits. Results. One hundred seven men were enrolled at 8 US sites; 82/107 (76.6%) completed the trial, and 79/107 (73.8%) successfully maintained PVR ≤ 150 ml for the trial duration. Patients were 77.1 ± 10.6 years old; 63/107 (58.9%) were dependent on Foley and 40/107 (37.4%) on intermittent catheterization for 36.0 ± 39.3 days and 30.2 ± 45.8 days, respectively. 25/107 (23.4%) discontinuations were primarily due to voluntary patient withdrawal 9/107 (8.4%), investigator-initiated withdrawal 8/107 (7.5%), or lack of effectiveness 4/107 (3.7%). During Spanner use, the mean Qmax was 11.2 ± 6.6, mean IPSS was 7.5 ± 6.4, and mean QOL was 2.0 ± 1.6. The most prevalent device-related adverse events were asymptomatic bacteriuria 25/107 (23.4%), discomfort 10/107 (9.4%), and urinary urgency 8/107 (7.5%). No device-related serious AEs were reported. Conclusions. This study demonstrates that catheter-dependent men with sufficient bladder contractility can achieve volitional voiding and successful bladder drainage using The Spanner Temporary Prostatic Stent for extended periods of time.

Publisher

Hindawi Limited

Subject

Urology,Obstetrics and Gynecology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3