Clinical Course of Dual-Chamber Implantable Cardioverter-Defibrillator Recipients followed by Cardiac Remote Monitoring: Insights from the LION Registry

Author:

Schwab Joerg O.1ORCID,Nägele Herbert2,Oswald Hanno3,Klein Gunnar3,Gunkel Oliver4,Lang Andreas5,Bauer Wolfgang R.6,Korb Paul7ORCID,Hauser Tino7

Affiliation:

1. Department of Therapeutic and Interventional Cardiology, Beta Clinic, The International Hospital, Bonn, Germany

2. Hospital Reinbek St. Adolf Stift, Reinbek, Germany

3. Hannover Medical School, Hannover, Germany

4. Hospital Frankfurt/Oder, Frankfurt/Oder, Germany

5. Joint Practice of Internistic and Cardiology, Erfurt, Germany

6. University Hospital Würzburg, Würzburg, Germany

7. Biotronik, Berlin, Germany

Abstract

Patients receiving dual-chamber implantable cardioverter-defibrillator (DR-ICD) therapy are at risk of developing atrial arrhythmia because of the increased rate of ventricular pacing and the progression of heart failure. Remote monitoring (RM) may identify the patients at highest risk of adverse events such as atrial arrhythmias. A total of 283 patients with 91,632 remote transmissions during a 15-month follow-up (FU) period enrolled in the LION registry were analysed. The parameters retrieved included the pacing mode, lower rate limit, percentage of atrial (%AP) and ventricular pacing (%VP), and percentage of atrial arrhythmia burden (%AB). In 92.7% of patients, the devices were initially programmed in DDD(R) or DDI(R), with changes of the pacing mode in 19.3% only. The lower rate limit remained stable in 80.4% of patients. At the first transmission, 8.7% of patients suffered from RM-detected atrial arrhythmia, which reached 36% during FU. The %AP was not associated with increased AB (p = 0.67), but the %VP was different in patients developing RM-detected atrial arrhythmia (26.9% vs. 13.7%, p < 0.00001). The %VP increased in 105 patients (significance level of α = 0.05), and 11 patients crossed the border of 50% VP. The LION substudy supports the concept of using RM in a real-world DR-ICD population. Remote monitoring of DR-ICDs allows for the quantification of the course of the pacing parameters and AB. Based on these observations, device parameters can be adjusted and optimized.

Funder

Biotronik

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3