Functionalized Fe3O4 Magnetic Nanoparticle Potentiometric Detection Strategy versus Classical Potentiometric Strategy for Determination of Chlorpheniramine Maleate and Pseudoephedrine HCl

Author:

Moustafa Azza A.1,Hegazy Maha A.1,Mohamed Dalia23,Ali Omnia2ORCID

Affiliation:

1. Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr-El Aini Street, 11562 Cairo, Egypt

2. Analytical Chemistry Department, Faculty of Pharmacy, October University for Modern Sciences and Arts (MSA), 11787 6th October City, Egypt

3. Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Ein Helwan, 11795 Cairo, Egypt

Abstract

Nanosized adsorbents when used in potentiometric methods of analysis usually show better performance rather than the traditional potentiometric approach; this is attributed to the high specific surface area of the nanomaterial used in addition to the lack of internal diffusion resistance, thus improving their adsorption capacity. In the presented work, a rapid and sensitive potentiometric determination of chlorpheniramine maleate (CPM) and pseudoephedrine hydrochloride (PSE) in pure form, in pharmaceutical preparation, and in biological fluid was developed based on functionalized magnetic nanoparticles (Fe3O4). This strategy was compared with the classical potentiometric strategy. Three types of sensors were constructed using phosphotungstic acid (PTA), β-cyclodextrin (β-CD), and β-cyclodextrin-conjugated Fe3O4 magnetic nanoparticles for the potentiometric determination of each of CPM and PSE. The prepared sensors were characterized in regards to their composition, life duration, working pH range, and response time. The sensors have demonstrated promising selectivity to CPM and PSE in the presence of pharmaceutical formulation excipients, plasma matrix, and a diversity of both organic and inorganic interfering materials. The developed sensors have displayed good responses. Statistical comparison of the achieved results with a reported method has revealed no significant difference regarding both accuracy and precision.

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3