Microaxial Flow Pumps for Cardiogenic Shock: Effects on Hemodynamics, Hemolysis, and End‐Organ Recovery

Author:

Parker Lauren E.ORCID,Kang Lillian,Milano Carmelo A.,Lobo Alejandro A.,Doberne Julie W.,Bishawi Muath,Jensen Christopher. W.ORCID,Patel Chetan B.,DeVore Adam D.,Russell Stuart D.,Katz Jason N.,Schroder Jacob N.

Abstract

Background. The Impella 5.5 offers a less invasive transvalvular approach to left ventricular mechanical support. End‐organ recovery and hemolysis have been well‐studied with durable left ventricular assist devices but effects of Impella 5.5 on these parameters are less well described. Methods. All Impella 5.5 recipients between August 2020 and June 2023 were reviewed from a single institution. Hemodynamics and laboratory values were compared between preimplant and prior to device removal. Hemolysis was defined as postoperative lactate dehydrogenase >1000 IU/L with concurrent plasma‐free hemoglobin >50 mg/dL. Paired Wilcoxon tests compared the median of differences between preimplant and pre‐explant values. Results. We studied 127 consecutive implants of the Impella 5.5. Thirty‐one patients had concomitant VA‐ECMO, and one received Impella 5.5 after durable LVAD explant; these cases were excluded. Our final cohort included 95 patients, with an average age of 55.29 ± 14.5 years. Median implant duration was 11 days (IQR:6–16 days). To avoid confounding hemodynamic factors, we restricted hemodynamic analysis to the 37 patients who received isolated Impella 5.5, excluding those with prior IABP, Impella CP, acute MI, or prior cardiac surgery. These patients experienced improvements from baseline in pulmonary vascular resistance (−77.03 dynes/sec/cm−5, p < 0.01) and wedge pressure (−6.5 mmHg, p < 0.01). Furthermore, cardiac index improved from baseline (+1.3, p < 0.01). In the total cohort (n = 95), pre‐explant creatinine (−0.2 mg/dL, p < 0.01) and ALT (−9.0 mg/dL, p < 0.01) decreased relative to values before the implant. Twenty‐three (24%) met criteria for hemolysis; however, none underwent device removal for clinically significant hemolysis. Takeback was required in 25 patients, 22 of which were for axillary hematoma. Conclusions. Impella 5.5 support acutely improved markers of end‐organ function and hemodynamics, including PVR.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3