High-Resolution Strain Measurement for Biomechanical Parameters Assessment in Native and Decellularized Porcine Vessels

Author:

Melchor Juan123ORCID,Soto Juan M.4ORCID,López-Ruiz Elena235ORCID,Suarez Javier1ORCID,Jiménez Gema2367ORCID,Antich Cristina67,Perán Macarena25ORCID,Marchal Juan A.2367ORCID,Rus Guillermo123ORCID

Affiliation:

1. Department of Structural Mechanics, University of Granada, Granada 18071, Spain

2. Instituto de Investigación Biosanitaria (ibs.GRANADA), Spain

3. Excellence Research Unit “Modeling Nature” (MNat), University of Granada, 18071, Spain

4. Department of Optics, Faculty of Physical Sciences, Complutense University of Madrid, Madrid 28040, Spain

5. Department of Health Sciences, University of Jaén, Jaén, Spain

6. Biopathology and Regenerative Medicine Institute (IBIMER), Centre for Biomedical Research, University of Granada, Granada, Spain

7. Department of Human Anatomy and Embryology, Faculty of Medicine, University of Granada, Granada, Spain

Abstract

Decellularized vascular scaffolds are promising materials for vessel replacements. However, despite the natural origin of decellularized vessels, issues such as biomechanical incompatibility, immunogenicity risks, and the hazards of thrombus formation still need to be addressed. In this study, we assess the mechanical properties of two groups of porcine carotid blood vessels: (i) native arteries and (ii) decellularized arteries. The biomechanical properties of both groups (n = 10, sample size of each group) are determined by conducting uniaxial and circumferential tensile tests by using an ad hoc and lab-made device comprising a peristaltic pump that controls the load applied to the sample. This load is regularly incremented (8 grams per cycle with a pause of 20 seconds after each step) while keeping the vessels continuously hydrated. The strain is measured by an image cross-correlation technique applied on a high-resolution video. The mechanical testing analyses of the arteries revealed significant differences in burst pressure between the native (1345.08±96.58 mbar) and decellularized (1067.79±112.13 mbar) groups. Moreover, decellularized samples show a significantly lower maximum load at failure (15.78±0.79 N) in comparison with native vessels (19.42±0.80 N). Finally, the average ultimate circumferential tensile also changes between native (3.71±0.37 MPa) and decellularized (2.93±0.18 MPa) groups. This technique is able to measure the strain in the regime of large displacements and enables high-resolution image of the local strains, thus providing a valuable tool for characterizing several biomechanical parameters of the vessels also applicable to other soft tissue presenting hyperelastic behaviours.

Funder

Ministerio de Educación, Cultura y Deporte

Publisher

Hindawi Limited

Subject

General Engineering,General Mathematics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3