Effects of Nonaqueous Phase Liquids Pollution on the Permeability and Microstructure of In-Filed and Laboratory Soaked Contaminated Clay Soils

Author:

Gao Yanbin12ORCID,Liu Jiadan12ORCID

Affiliation:

1. Department of Geotechnical Engineering College of Civil Engineering, Tongji University, Shanghai 200092, China

2. Key Laboratory of Geotechnical and Underground Engineering of the Ministry of Education, Tongji University, Shanghai 200092, China

Abstract

The fact that the permeability and microstructure properties of clay will be changed by NAPL (Nonaqueous Phase Liquids) pollution draws high attention in the study of the interaction between NAPL and contaminated soil. Through in-field contaminated clay soils from vinyl chloride and 1, 1, 2-trichloroethane-contaminated site in Shanghai, the variation of the content of vinyl chloride and 1, 1, 2-trichloroethane pollutants in clay with depth was obtained. The change of plasticity, permeability, and microstructure properties of the clay samples contaminated by vinyl chloride and 1, 1, 2-trichloroethane were investigated in detail. The measured test results were compared with the uncontaminated clay and indoor soaked contaminated clay samples by TCE (Trichloroethylene). The test results showed that the microstructure characteristics of clay were changed under the influence of the content of TCE, vinyl chloride, and 1, 1, 2-trichloroethane. The total porosity, accumulative pore volume, and the content of the macroporosity percentage of clay soils showed an increasing trend. The flocculation structure of contaminated clay samples was observed, but there were no overhead pores and connected cracks. Volatile organic pollutants were detected in both field and indoor contaminated clay samples. The plastic limit and liquid limit of each layer of contaminated samples decreased slightly, the plastic index did not change significantly, and the pore ratio and permeability coefficient increased gently. At the same time, the clay shrinkage was aggravated by TCE pollution, and cracks appeared on the surface of soil samples. However, no connected cracks were formed. Test results indicated that the self-developed improved permeability test device can be used to test the permeability coefficient of clay samples with shrinkage and to crack by NAPL pollution. The permeability coefficient showed an increasing trend, though the increase was not at the level of magnitude.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

General Earth and Planetary Sciences

Reference36 articles.

1. Environmental geotechnics: state-of-the-art of theory, testing and application to practice;T. Liang;China Civil Engineering Journal,2016

2. Mechanism by which organic liquids increase the hydraulic conductivity of compacted clay materials;K. W. Bromn;Soil Science Society of America Journal,1987

3. The influence of various concentrations of organic liquids on the hydraulic conductivity of compacted clay;J. J. Bowders;Geotechnical Engineering,1958

4. The influence of selected organic liquids on the permeability of clay liners;K. W. Brown

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3