Infectious Risk of the Hospital Environment in the Center of Morocco: A Case of Care Unit Surfaces

Author:

Jaouhar Samira12ORCID,El Ouali Lalami Abdelhakim2ORCID,Ouarrak Khadija3ORCID,Bouzid Jawad4ORCID,Maoulouaa Mohammed3ORCID,Bekhti Khadija1ORCID

Affiliation:

1. Laboratory of Microbial Biotechnology, Faculty of Science and Technology, Sidi Mohammed Ben Abdellah University Fez, Morocco

2. Higher Institute of Nursing and Health Professions, Fez, Morocco

3. Medical Analysis Laboratory of the Meknes Hospital Center, Regional Health Department Fez-Meknes, Fez, Morocco

4. Laboratory of Health Sciences and Technologies, Higher Institute of Health Sciences, Hassan First University, Settat, Morocco

Abstract

Background. Equipment and hospital surfaces constitute a microbial reservoir that can contaminate hospital users and thus create an infectious risk. The aim of this work, which was carried out for the first time at a hospital in Meknes (regional hospital in the center of Morocco), is to evaluate the microbiological quality of surfaces and equipment in three potential risk areas (burn unit, operating room, and sterilization service). Methods. This study was carried out over a period of 4 months (February–May 2017). A total of 60 samples were taken by swabbing according to the standard (ISO/DIS 14698-1 (2004)) in an environment of dry area and equipment after biocleaning. Isolation and identification were performed according to conventional bacteriological methods and by microscopic observation for fungi. Results. The study showed that 40% of surface samples were contaminated after biocleaning. The burn unit recorded a percentage of 70% contamination (p value <0.001), 13% for the sterilization service, and 7% for the operating room. 89% of the isolates were identified as Gram-positive bacteria against 11% for fungi (p value <0.001). Bacterial identification showed coagulase-negative staphylococci (32%), Bacillus spp. (16%), Corynebacterium (8%), and oxidase-negative Gram-positive bacillus (40%) while fungal identification showed Aspergillus niger (n = 2) and Aspergillus nidulans (n = 1). Conclusion. To control the infectious risk related to equipment and hospital surfaces, it would be necessary to evaluate the disinfection protocol applied in these units.

Publisher

Hindawi Limited

Subject

General Agricultural and Biological Sciences,General Environmental Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3