Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan

Author:

Zhao Yusen1,Wang Yaoyi1,Xu Yuanbo2,Zhao Yijie3,Qu Yingwu1,Zhang Hua1,Zhang Zhimin1,Hu Zhenshun1,Zhu Xiaolong1,Cui Shujun1,Xie Jin4ORCID

Affiliation:

1. Department of Medical Imaging, The First Affiliated Hospital of Hebei North University, Zhangjiakou City 075000, Hebei Province, China

2. Return Visit Center, The First Affiliated Hospital of Hebei North University, Zhangjiakou City 075000, Hebei Province, China

3. Library Information Department, Hebei North University, Zhangjiakou City 075000, Hebei Province, China

4. Medical Imaging Center, Central Hospital Affiliated to Shandong First Medical University, Jinan City 250013, Shandong Province, China

Abstract

Objective. To explore the diagnostic value for chronic kidney disease (CKD) between 640-slice computed tomography (CT) kidney scan and conventional CT scan. Methods. A total of 120 CKD patients who received kidney plain scan plus enhanced examination in the CT room of the Medical Imaging Department of our hospital from June 2019 to September 2019 were selected and randomly divided into the experimental group (n = 60) and the control group (n = 60). Patients in the control group received the conventional CT plain scan and enhanced scan, and for patients in the experimental group, CT plain scan was performed first, the range of 640-slice CT dynamic volume scan was determined, and after bolus injection of contrast agent, dynamic volume scan was performed for scanning in the cortical phase, myeloid phase, and secretory phase. The imaging quality and effective scanning dose were compared between the two modalities, and the relationship between CT values obtained from 640-slice CT scan and conventional CT scan and the renal impairment was analyzed. Results. Compared with the control group, the image quality of 640-slice CT scan conducted in the experimental group was significantly better ( P < 0.05 ); the effective radiation doses of the experimental group and the control group were, respectively, (1.89 ± 0.32) mSv and (3.26 ± 0.47) mSv, indicating that the dose was significantly lower in the experimental group than in the control group (t = 18.664, P < 0.001 ), and the correlation analysis showed that the relationship between the sum of CT values in the cortical phase of both kidneys and kidney injury in the experimental group was r = 0.835, P < 0.001 . Conclusion. Both 640-slice CT kidney scan and conventional CT scan can be used in the diagnosis of CKD. 640-slice CT has a lower radiation dose, better image quality, and higher application value.

Funder

Application of 640 Slice Volume CT in Dynamic Volume Scanning of Kidney

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3