In VivoComparison of 23- and 25-Gauge Sutureless Vitrectomy Incision Architecture Using Spectral Domain Optical Coherence Tomography

Author:

Teixeira Anderson123,Rezende Flavio A.45,Salaroli Camila12,Souza Nonato1,Sousa Benedito Antonio3,Allemann Norma26

Affiliation:

1. Teixeira Oftalmologia, SDS Bloco D No 27, Sala 306, 70392-901 Brasília, DF, Brazil

2. Department of Ophthalmology, Universidade Federal de São Paulo, São Paulo, SP, Brazil

3. Department of Ophthalmology, Universidade Católica de Brasília, Brasília, DF, Brazil

4. Department of Ophthalmology, Hôpital Maisonneuve-Rosemont, Université de Montréal, Montréal, QC, Canada

5. Department of Ophthalmology, Pontifícia Universidade Católica, Rio de Janeiro, RJ, Brazil

6. Department of Ophthalmology, University of Illinois at Chicago, Chicago, IL, USA

Abstract

Purpose. To investigate thein vivoincision architecture using spectral domain optical coherence tomography (SD-OCT) in 23-gauge and 25-gauge transconjunctival suturelesspars planavitrectomy (TSPPV).Methods. A prospective observational study of 22 eyes of 22 patients that underwent three-port 25-gauge (10 eyes) or 23-gauge (12 eyes) TSPPV was performed. The three sclerotomies sites in each eye were analyzed by Corneal Adapter Model (CAM) RTVue SD-OCT (Optovue Inc., Fremont, CA, USA) with wound cross-section images (longitudinal and transversal) on days 1, 7, and 30 postoperatively. Transversal and longitudinal length, location, angle between the conjunctival surface tangent and the incision plane, and architecture deformations were evaluated.Results. All patients (22 eyes) completed the study and surgeries lasted less than 60 minutes. All wounds were obliquely performed, 23-gauge mean angle was 23 ± 5°, and 25-gauge angule was 21 ± 4°. Twenty-three-gauge sclerotomy transversal mean length was 1122 ± 242 μm and 25-gauge transversal sclerotomy mean length was 977 ± 174 μm; 23-gauge longitudinal mean length was 363 ± 42 μm and 25-gauge longitudinal sclerotomy mean length was 234 ±19 μm; 23-gauge open wound thickness mean was 61 ± 28 μm and 25-gauge open wound thickness mean was 22 ± 6 μm. All results were statistically significant (P<0.05). No vitreous incarceration or silicone oil residue was observed in incision sites with both gauges.Conclusions. The 23-gauge and 25-gauge architectural wound constructions were well visualized using CAM SD-OCT. Statistical differences between the two gauges were observed throughout the study period.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3