A Novel Role for Corneal Pachymetry in Planning Cataract Surgery by Determining Changes in Spherical Equivalent Resulting from a Previous LASIK Treatment

Author:

Hammer Arthur1ORCID,Heeren Tjebo F. C.1ORCID,Angunawela Romesh12ORCID,Marshall John3ORCID,Saha Kamran1ORCID

Affiliation:

1. Moorfields Eye Hospital NHS Foundation Trust, London, UK

2. OCL Vision, London, UK

3. University College London, Institute of Ophthalmology, London, UK

Abstract

Objectives. To provide a metric to differentiate between hyperopic and myopic ablation of a prior LASIK treatment based on the corneal pachymetry profile after laser vision correction (LVC). Methods. Pachymetry data were retrospectively recovered from patients who had previous LASIK for refractive purposes between 2019 and 2020. Patients with any corneal disorder were excluded. Ablation spherical equivalent was predicted from the central to semiperipheral corneal thickness (CPT) ratio, both values were provided by using the Pentacam user interface software (UI), and values were computed from extracted raw pachymetry data. Results. Data of 157 eyes of 81 patients were collected, of which data were analysed for 73 eyes of 73 patients to avoid concurrence of measurements in both eyes per subject (42% female; mean age 40.9; SD 12.8). The CPT ratio cutoff for distinction between myopic and hyperopic LASIK was 0.86 for Pentacam UI data. Sensitivity and specificity were 0.7 and 0.95, respectively. Accuracy increased with computation of the CPT ratio based on extracted raw data with sensitivity and specificity of 0.87 and 0.99, respectively. There was a marked linear correlation between the CPT ratio and the ablation spherical equivalent (R2 = 0.93). Conclusions. CPT ratio cutoffs can correctly classify if a cornea previously had a hyperopic versus myopic LASIK surgery and estimate the ablation spherical equivalent of such treatment. This could prove useful for increased accuracy of intraocular lens (IOL) calculations for patients with no historical data of their prior LVC surgery at the time of cataract surgery planning.

Publisher

Hindawi Limited

Subject

Ophthalmology

Reference35 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Corneal biomechanics and diagnostics: a review;International Ophthalmology;2024-03-13

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3