Disposable Nonenzymatic Uric Acid and Creatinine Sensors Using μPAD Coupled with Screen-Printed Reduced Graphene Oxide-Gold Nanocomposites

Author:

Income Kamolwich12,Ratnarathorn Nalin1,Khamchaiyo Napassawan1,Srisuvo Chanut1,Ruckthong Leela1,Dungchai Wijitar1ORCID

Affiliation:

1. Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, 126 Pracha-utid Road, Bang Mod, Thungkru, Bangkok 10140, Thailand

2. Department of Primary Industries and Mines, Ministry of Industry, Bangkok 10400, Thailand

Abstract

Uric acid (UA) and creatinine are the imperative biological substance for clinical monitoring and diagnosis. Measuring the ratio between uric acid and creatinine in urine helps differentiate acute uric acid nephropathy from the hyperuricemia that secondarily occurs to renal failure. In general, the ratio is greater than 0.9 in acute uric acid nephropathy and less than 0.7 in hyperuricemia. In this work, disposable nonenzymatic screen-printed reduced graphene oxide-gold nanocomposites electrodes were firstly developed for the quantitative analysis of uric acid. Our sensors were also coupled with the paper-based colorimetric sensor of the determination of creatinine. Hence, an alternative high-throughput screening test for the uric acid to creatinine ratio with high sensitivity, specificity, simplicity, and rapidity was developed. Under the optimum conditions, our disposable nonenzymatic screen-printed electrode for the determination of uric acid shows the acceptable analytical performance in a wide range of linearity (2.5-1,000 μM) with a low detection limit of 0.74 μM. Our electrodes also showed no interference from common physiologic compound in urine. The determination of creatinine has been developed using Jaffé reaction between the creatinine and picric acid in alkaline condition. The alkaline picrate color on μPAD changed from yellow to orange in the presence of creatinine and the orange intensity is directly proportional to the creatinine amount in a linearity range of 0.20-6.0 mM as a detection limit of 180 μM. Finally, our device has been utilized to determine uric acid and creatinine simultaneously in control urine samples with acceptable result.

Funder

King Mongkut's University of Technology Thonburi

Publisher

Hindawi Limited

Subject

Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3