Affiliation:
1. Institute for Environmental and Human Health Protection, Faculty of Chemistry, University of Gdansk, Wita Stwosza 63, 80-308 Gdansk, Poland
Abstract
Even though the methodology used for the determination ofβ-blockers andβ-agonists in environmental samples is based mainly on solid-phase extraction (SPE) and gas chromatography or liquid chromatography with mass spectrometric detection, the available literature data on the applied SPE procedures is rather sparse. In this paper such comparison is presented. Moreover, the usefulness of the eight SPE cartridges for the determination of fiveβ-blockers (acebutolol, atenolol, metoprolol, nadolol, and propranolol) and twoβ-agonists (salbutamol and terbutaline) in environmental aqueous samples using GC techniques is tested. Among them, three (the trifunction sorbent Strata Screen C, the copolymers LiChrolut EN, and the functionalized copolymer Isolute ENV+) were used for the first time for this purpose. It was confirmed that polystyrene-divinylbenzene-N-vinylpyrrolidone copolymers (PS-DVB-VP, Strata-X, and Oasis HLB cartridges) have a better potential than a cation-exchange sorbent for the extraction of the target drugs from environmental water samples. However, it should be stressed out that the direct application of the tested SPE conditions for the analysis of real environmental water samples is not possible, and such parameters, like volume of loading sample, appropriate solvents for washing and elution steps, and so forth, must be optimized again in order to achieve satisfactory recovery values for the target compounds.
Funder
Polish Ministry of Research and Higher Education
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献