Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration

Author:

Huang Lina1ORCID,Li Hanke2,Li Yuhang2,Ren Peng2,Yi Lezhou1,Chen Yang1,Ma Tongmei2ORCID

Affiliation:

1. Guangzhou Customs Technology Center, Huacheng Avenue 66, Zhujiang New Town, Tianhe District, Guangzhou 510623, China

2. School of Chemistry and Chemical Engineering, South China University of Technology, Wushan Road 381, Tianhe District, Guangzhou 510640, China

Abstract

Background. Organic tin compounds (OTCs), a group of high-risk hazardous substances, are highly concerned in safety regulation of consumer products especially for toys because they can cause serious damage to organs after prolonged or repeated exposure. Gastric juice migration is nowadays widely implemented to assess organic tin intake from toys or food-contact materials; however, the followed up detection method using sodium tetraethylborate [NaB(Et4)] as a derivatization agent may directly lead to false positive of monomethyltins (MMT). Objective. In order to avoid the phenomena of false positive of MMT in the course of laboratory testing of toys, it is necessary and important to perform relative experimental and theoretical studies to reveal the cause of false positive of MMT. Method. With metal tin powder as a representative of inorganic tin which existed in real samples, it was treated with artificial gastric juice (0.07 mol/L·HCl), followed by ethyl derivatization using sodium tetraethylborate [NaB(Et)4] and then analyzed by gas chromatography-mass spectrometry (GC-MS) according to the procedure specified in the standard of EN 71-3:2013+A3:2018 issued by the European Committee for Standardization (CEN). Results. Without any OTCs in the starting materials, MMT false positive can be reproduced by detecting 0.56 mg/L of triethylmethyltin (TEMT) together with approximately 1000 mg/L of tetraethyltin (TeET), which is similar to real samples. Further, it is demonstrated that the detected amount of TEMT is linearly related with the added amount of NaB(Et)4, and that the formation of TEMT (methyl derivative) is easier than TeET (ethyl derivative) even though the ethyl group is present in a larger amount than the methyl group. Conclusions. The phenomena of MMT false positive which occurred in the laboratory testing of toys is mainly because that TEMT is highly likely to be obtained from the reaction of inorganic tin and trace level of methylation agent impurities contained in the derivatization reagent—NaB(Et)4. To avoid MMT false positive, it is concluded that the maximum acceptable mole ratio of methylation agent impurities contained in NaB(Et)4 is approximately 0.028%. This research is helpful to be aware of methylation impurities and is favorable to avoid false judgment caused by MMT false positive in routine analysis of toys.

Funder

National Key Research and Development Program Sub-Project

Publisher

Hindawi Limited

Subject

Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3