Adequacy of the Fogging Test in the Detection of Clinically Significant Hyperopia in School-Aged Children

Author:

Esteves Leandro João1,Meira Jorge1ORCID,Ferreira Carla Sofia12,Santos-Silva Renato12ORCID,Freitas-Costa Paulo13,Magalhães Augusto1,Breda Jorge1,Falcão-Reis Fernando12

Affiliation:

1. Department of Ophthalmology, São João Hospital, Porto, Portugal

2. Department of Surgery and Physiology, Faculty of Medicine, University of Porto, Porto, Portugal

3. Department of Anatomy, Faculty of Medicine, University of Porto, Porto, Portugal

Abstract

Purpose. To evaluate the efficacy of the “fogging test,” performed with a +2 diopters (D) lens, in the exclusion of clinically significant hyperopia in school-aged children. Methods. We studied 54 children between 5 and 11 years of age, with 10/10 best-corrected bilateral visual acuity (VA) without significant degree of correction. VA was assessed in each eye with a “bilateral” +2 D sphere over-refraction followed by cycloplegic retinoscopy. The capacity of the test to detect hyperopia of ≥+2 D and ≥+1.5 D was evaluated by examining the respective receiver operating characteristic (ROC) curves and sensitivity and specificity values for different cutoff values of VA. Results. For the detection of hyperopia ≥+2 D, the area under the ROC curve (AUC) was 0.955 (p0.001). The VA cutoff with best discriminative capacity was ≥5/10, with a sensitivity of 100%, specificity of 79%, positive predictive value (PPV) of 57%, and negative predictive value (NPV) of 100%. In respect of ≥+1.5 D hyperopia, the test capacity was lower (AUC = 0.832; p0.001). The best VA cutoff was also of ≥5/10, with a PPV of 81% and a NPV of 85%. Conclusion. The accuracy of the test was high for the evaluation of ≥+2 D hyperopia but lower for ≥+1.5 D hyperopia. For the detection of ≥+2 D hyperopia, the VA cutoff of <5/10 may permit the exclusion of clinically significant hyperopia in selected children, without the need for cycloplegia. For the same cutoff, the PPV was low, meaning that in children with ≥5/10 VA cycloplegic refraction remains obligatory.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3