CT Angiography Analysis of Axillary Artery Diameter versus Common Femoral Artery Diameter: Implications for Axillary Approach for Transcatheter Aortic Valve Replacement in Patients with Hostile Aortoiliac Segment and Advanced Lung Disease

Author:

Tayal Rajiv1,Iftikhar Humayun1,LeSar Benjamin1,Patel Rahul1,Tyagi Naveen1,Cohen Marc1,Wasty Najam1

Affiliation:

1. Division of Cardiology, Newark Beth Israel Medical Center, Newark, NJ 07112, USA

Abstract

Objective.The use of the axillary artery as an access site has lost favor in percutaneous intervention due to the success of these procedures from a radial or brachial alternative. However, these distal access points are unable to safely accommodate anything larger than a 7-French sheath. To date no studies exist describing the size of the axillary artery in relation to the common femoral artery in a patient population. We hypothesized that the axillary artery is of comparable size to the CFA in most patients and less frequently diseased.Methods.We retrospectively reviewed 110 CT scans of the thoracic and abdominal aorta done at our institution to rule out aortic dissection in which the right axillary artery, right CFA, left axillary artery, and left CFA were visualized. Images were then reconstructed using commercially available TeraRecon software and comparative measurements made of the axillary and femoral arteries.Results.In 96 patients with complete data, the mean sizes of the right and left axillary artery were slightly smaller than the left and right CFA. A direct comparison of the sizes of the axillary artery and CFA in the same patient yielded a mean difference of 1.69 mm ± 1.74. In all patients combined, the mean difference between the axillary artery and CFA was 1.88 mm on the right and 1.68 mm on the left. In 19 patients (19.8%), the axillary artery was of the same caliber as the associated CFA. In 8 of 96 patients (8.3%), the axillary artery was larger compared to the CFA.Conclusions.Although typically smaller, the axillary artery is often of comparable size to the CFA, significantly less frequently calcified or diseased, and in almost all observed cases large enough to accommodate a sheath with up to 18 French.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3