Intra- and Inter-Rater Reliability of Processing Ultrasound Tissue Characterization Scans in Midportion Achilles Tendinopathy

Author:

Paantjens Marc Adriaan12ORCID,Helmhout Pieter Herman3,Gerardus Backx Franciscus Jacobus2,Willibrord Martens Meindert Thomas Annechien4,Dongen Joeri Paulus Adrianus van5,Petrus Bakker Eric Wilhelmus6

Affiliation:

1. Sports Medicine Centre, Training Medicine and Training Physiology, Royal Netherlands Army, Utrecht, Netherlands

2. Department of Rehabilitation, Physical Therapy Science and Sports, University Medical Center Utrecht, Utrecht, Netherlands

3. Centre of Excellence, Training Medicine and Training Physiology, Royal Netherlands Army, Utrecht, Netherlands

4. Fontys University of Applied Science, Eindhoven, Netherlands

5. National Institute of Musculoskeletal Ultrasound, Vianen, Netherlands

6. Department Epidemiology and Data Science, Division EPM, University Medical Center Amsterdam, Amsterdam, Netherlands

Abstract

Purpose. Ultrasound tissue characterization (UTC) is used to visualize and quantify the Achilles tendon structure. We investigated the intra-rater and inter-rater reliability of UTC for quantifying the midportion tendon structure and the area of maximum degeneration (AoMD) in military personnel with midportion Achilles tendinopathy. Method. UTC scans of 50 patients (16–60 years) were processed twice by rater 1 and once by rater 2. First, the midportion tendon structure was quantified and subsequently the AoMD. The intraclass correlation coefficient (ICC) was calculated for echo-types I, II, III, IV, aligned fibrillar structure (echo-types I + II), and disorganized tendon structure (echo-types III + IV). Results. For midportion tendon structure, all ICC values were excellent for intra-rater reliability (range: 0.97 to 0.99) and inter-rater reliability (range: 0.98 to 0.99). Regarding the AoMD, intra-rater reliability showed excellent ICC values for all echo-types (range: 0.94 to 0.98) except for echo-type II (0.85). Inter-rater reliability showed excellent ICC values for all echo-types (range: 0.92 to 0.98). Conclusion. Processing of UTC scans is highly reliable in quantifying the midportion Achilles tendon structure and the AoMD.

Publisher

Hindawi Limited

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3