Analysis and Research on the Centimeter Band Receiver Amplitude Calibration Method

Author:

Wang Kai123ORCID,Chen Maozheng123,Ma Jun123,Duan Xuefeng123,Wang Yang123,Cao Liang123,Yan Hao123,Xiang Binbin12ORCID

Affiliation:

1. Xinjiang Astronomical Observatory, Chinese Academy of Sciences, Urumqi 830011, China

2. Key Laboratory of Radio Astronomy, Chinese Academy of Sciences, Nanjing 210008, China

3. Xinjiang Key Laboratory of Microwave Technology, Urumqi 830011, China

Abstract

The receiver is a signal receiving device in a radio telescope system. As an important parameter to characterize the receiver performance, noise temperature is very practical to calibrate accurately. The traditional receiver noise temperature calibration method is the cold and ambient load method. Through the establishment of K-band ambient receiver, and its amplitude calibration test platform of the cold and ambient load method, chopper wheel method, and ambient and hot load method, comparison and analysis of the above three methods were carried out. The test and calculation results show that the test accuracy of the cold and ambient load method is about 1.3%, that of the chopper wheel method (nonlow elevation) is about 3%, and that of the ambient and hot load method is about 9%. The test accuracy of the ambient and hot load method is slightly lower than that of the above two methods. The analysis is mainly due to the uncertainty of the hot load temperature and the small temperature difference between the two loads, which leads to the deterioration of the overall accuracy. But the advantage is that the method can perform real-time calibration in the process of observation, and it is easier to implement than the traditional cold and ambient load method. The results of noise temperature measurement are compared with those of theoretical calculation, the error is basically within 10%, and it can satisfy the demand of the noise temperature test. In the future, we expect that on the basis of increasing the hot load temperature, further experiments were carried out on the thermostatic treatment of hot load and the accuracy of temperature acquisition, and finally we hope that this method can better meet the testing requirements of receiver noise temperature and radio source amplitude calibration.

Funder

Xinjiang Key Laboratory of Radio Astrophysics

Publisher

Hindawi Limited

Subject

Space and Planetary Science,Astronomy and Astrophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献