Kidney Modelling for FDG Excretion with PET

Author:

Qiao Huiting,Bai Jing,Chen Yingmao,Tian Jiahe

Abstract

The purpose of this study was to detect the physiological process of FDG's filtration from blood to urine and to establish a mathematical model to describe the process. Dynamic positron emission tomography scan for FDG was performed on seven normal volunteers. The filtration process in kidney can be seen in the sequential images of each study. Variational distribution of FDG in kidney can be detected in dynamic data. According to the structure and function, kidney is divided into parenchyma and pelvis. A unidirectional three-compartment model is proposed to describe the renal function in FDG excretion. The time-activity curves that were picked up from the parenchyma, pelvis, and abdominal aorta were used to estimate the parameter of the model. The output of the model has fitted well with the original curve from dynamic data.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging