Assessment Parameters for Arrayed Pulse Wave Analysis and Application in Hypertensive Disorders

Author:

Bi Zi-Juan1ORCID,Yao Xing-Hua1ORCID,Hu Xiao-Juan2ORCID,Yuan Pei1ORCID,Guo Xiao-Jing1ORCID,Guo Zhi-Ling1ORCID,Wang Si-Han1ORCID,Li Jun1ORCID,Shi Yu-Lin1ORCID,Li Jia-Cai1ORCID,Cui Ji1ORCID,Xu Jia-Tuo1ORCID

Affiliation:

1. Basic Medicine College, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China

2. Shanghai Innovation Center of TCM Health Service, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China

Abstract

Study on the objectivity of pulse diagnosis is inseparable from the instruments to obtain the pulse waves. The single-pulse diagnostic instrument is relatively mature in acquiring and analysing pulse waves, but the pulse information captured by single-pulse diagnostic instrument is limited. The sensor arrays can simulate rich sense of the doctor’s fingers and catch multipoint and multiparameter array signals. How to analyse the acquired array signals is still a major problem in the objective research of pulse diagnosis. The goal of this study was to establish methods for analysing arrayed pulse waves and preliminarily apply them in hypertensive disorders. While a sensor array can be used for the real-time monitoring of twelve pulse wave channels, for each subject in this study, only the pulse wave signals of the left hand at the “guan” location were obtained. We calculated the average pulse wave (APW) per channel over a thirty-second interval. The most representative pulse wave (MRPW) and the APW were matched by their correlation coefficient (CC). The features of the MRPW and the features that corresponded to the array pulse volume (APV) parameters were identified manually. Finally, a clinical trial was conducted to detect these feature performance indicators in patients with hypertensive disorders. The independent-samples t-tests and the Mann–Whitney U-tests were performed to assess the differences in these pulse parameters between the healthy and hypertensive groups. We found that the radial passage (RP) APVh1, APVh3, APVh4, APVh3/h1 (P < 0.01), and APVh4/h1 (P < 0.05) were significantly higher in the hypertensive group than in the healthy group; the intermediate passage (IP) APVh4, APVh3/h1 (P < 0.05), and APVh4/h1 (P < 0.01) and the mean APVh3, APVh3/h1 (P < 0.05), and APVh4/h1 (P < 0.01) were significantly higher in the hypertensive group than in the healthy group, and the ulnar passage (UP) APVh4/h1 (P < 0.05) was clearly elevated in the hypertensive group. These results provide a preliminary validation of this novel approach for determining the APV by arrayed pulse wave analysis. In conclusion, we identified effective indicators of hypertensive vascular function. Traditional Chinese medicine (TCM) pulses comprise multidimensional information, and a sensor array could provide a better indication of TCM pulse characteristics. In this study, the validation of the arrayed pulse wave analysis demonstrates that the APV can reliably mirror TCM pulse characteristics.

Publisher

Hindawi Limited

Subject

Complementary and alternative medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3