Detection and Blocking of Replay, False Command, and False Access Injection Commands in SCADA Systems with Modbus Protocol

Author:

L Rajesh1ORCID,Satyanarayana Penke1ORCID

Affiliation:

1. Department of Electronics and Communication Engineering, Koneru Lakshmaiah Education Foundation, K L Deemed to be University, Vaddeswaram, Guntur 522 502, Andhra Pradesh, India

Abstract

Industrial control systems (ICS) are being used for surveillance and controlling numerous industrial process plants in national critical infrastructures. Supervisory control and data acquisition (SCADA) system is a core component in ICS systems for continuous monitoring and controlling these process plants. Legacy SCADA systems are working in isolated networks and using proprietary communication protocols which made them less exposed to cyber threats. In recent times, these ICS systems have been connected to Internet and corporate networks for data sharing and remote monitoring. They are also using open protocols and operating systems. This leads to vulnerabilities of the system to cyberattacks. Cybersecurity threats are more prevalent than ever in ICS systems. These attacks may be external or internal. Modbus is a widely deployed communication protocol for SCADA communications. There is no security in design of Modbus protocol, and it is vulnerable to numerous cyberattacks. In this paper, we worked for False Command Injection attack, False Access Injection attack, and replay attacks on Modbus protocol. Initially, a real-time SCADA testbed was set up, and we envisaged the impact of these attacks on Modbus protocol data using the testbed. In this work, we used local area network (LAN) environment only for simulating the attacks. We assumed that the attacks penetrated the LAN network. We proposed and developed (a) a method to detect replay attacks by incorporating time stamp and sequence number in Modbus communications and (b) a frame filtering module which will block unauthorized attacks like False Command Injection and False Access Injection attacks to reach programmable logic controller (PLC). Numbers of attacks were simulated and the performance of the method was measured using attack block rate (ABR). It blocked 97% of malicious Modbus transactions or attacks to reach the PLC. It protects SCADA systems from attackers, which is a core component of industrial control systems. The solution enhanced the security of SCADA systems with Modbus protocol.

Funder

Koneru Lakshmaiah Education Foundation

Publisher

Hindawi Limited

Subject

Computer Networks and Communications,Information Systems

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3