Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses

Author:

Lee Jae Hyuck1,Chung Ho Seok2,Moon Su Young3,Park So Young3,Lee Hun3,Kim Jae Yong3,Tchah Hungwon3ORCID

Affiliation:

1. Department of Ophthalmology, HanGil Eye Hospital, Incheon, Republic of Korea

2. Department of Ophthalmology, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Republic of Korea

3. Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea

Abstract

Purpose. To evaluate the clinical outcomes after bilateral mix-and-match cataract surgery using extended depth of focus (EDOF) and diffractive multifocal (DMF) intraocular lenses (IOLs). Setting. Asan Medical Center, Seoul, South Korea. Design. Prospective clinical study. Methods. Thirty-seven patients underwent TECNIS Symfony EDOF IOL (ZXR00) implantation in the dominant eye, and TECNIS +3.25 DMF IOL (ZLB00) implantation in the nondominant eye. Patients were followed up for 3 months; uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA), contrast sensitivity, defocus curves, stereopsis, and patient satisfaction were assessed. Results. At 3 months, the mean logarithm of the minimum angle of resolution (logMAR) of UDVA was 0.07 ± 0.09 in EDOF IOL eyes, 0.12 ± 0.11 in DMF IOL eyes, and 0.02 ± 0.05 in both eyes. UIVA was 0.11 ± 0.11 in EDOF IOL eyes, 0.16 ± 0.12 in DMF IOL eyes, and 0.04 ± 0.07 in both eyes. UNVA was 0.25 ± 0.15 in EDOF IOL eyes, 0.22 ± 0.16 in DMF IOL eyes, and 0.13 ± 0.13 in both eyes. Thirty patients (81.1%) were more than satisfied with near vision, and 8 patients (21.6%) complained of severe glare and halo. Spectacle independence for near vision was achieved in 34 patients (91.9%), and 31 patients (83.8%) had better than a 50-second arc of stereopsis. Conclusion. Mix-and-match cataract surgery with EDOF and DMF IOL implantation provided good visual outcomes for all distances. Additionally, excellent patient satisfaction was achieved with a high level of spectacle independence and acceptable photic phenomena.

Funder

Ministry of Education, Science and Technology

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3