Five Years Follow-Up of Acrysof Cachet® Angle-Supported Phakic Intraocular Lens Implantation for Myopia Correction

Author:

Musayeva Aytan12ORCID,Riedl Jana C.1ORCID,Gericke Adrian1ORCID,Vossmerbaeumer Urs1ORCID

Affiliation:

1. Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Langenbeckstr. 1, Mainz 55131, Germany

2. Schepens Eye Research Institute, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA 02114, USA

Abstract

Purpose. The Acrysof Cachet® angle-supported phakic intraocular lens (pIOL) (Alcon Laboratories, Inc., Fort Worth, TX) is designed to correct high refractive errors in human eyes. The aim of this study was to evaluate the outcome of AcrySof Cachet® angle-supported pIOL implantation with particular regard to efficacy and safety of the implant over a 60-month follow-up period. Design. Retrospective consecutive clinical case study. Methods. Prior to pIOL implantation, patients had a complete ophthalmologic examination including objective and subjective refraction, uncorrected visual acuity (UCVA) and corrected distance visual acuity (CDVA), endothelial cells density (ECD), slit lamp photography, optical coherence tomography (OCT), Scheimpflug digital videokeratoscopy, optical biometry, slit lamp examination, intraocular pressure (IOP) measurement, and pupillometry. Postoperatively, patients received yearly a complete eye examination. Results. Thirty-one eyes of 16 patients were included in this study. The mean age was 36.2 ± 8.1 years. UCVA (logMAR) improved from 1.33 ± 0.20 before surgery to 0.08 ± 0.14 one year after surgery and was 0.20 ± 0.20 five years after surgery. CDVA (logMAR) improved from 0.10 ± 0.10 before surgery to 0.05 ± 0.13 one year after surgery and was 0.04 ± 0.14 five years postoperatively. The mean percentage of endothelial cells loss (ECL) was 11.51% over the first year and 15.95% five years after surgery. There were no intraoperative complications in any of the eyes. Conclusions. Our results up to five years after implantation of the AcrySof Cachet® angle-supported pIOL demonstrated very good outcomes in all above shown measurements, including CDVA, UCVA, and ECD. However, since major endothelial cell loss may occur in some patients with this type of pIOL, regular follow-up visits are required.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3