Differences in Trocar Positioning within the Vertebral Body Using Two Different Positioning Methods: Effect on Trainee Performance

Author:

Komemushi Atsushi1,Takizawa Kenji2,Tanaka Norimitsu3,Yoshimatsu Misako2,Yagihashi Kunihiro2,Ogawa Yukihisa2,Fujikawa Atsuko2,Uejima Iwao2,Koike Yuya2,Tamura Taiji4,Takahashi Makoto5,Koizumi Jun6,Yamakado Koichiro7,Nakatsuka Seishi8,Yoshioka Tetsuya9,Hirota Shozo10,Nakamura Kenji11,Nakajima Yasuo2,Kuribayashi Sachio8,Kariya Shuji1,Tanigawa Noboru1,Sawada Satoshi1

Affiliation:

1. Department of Radiology, Kansai Medical University, Moriguchi, Osaka 570-8507, Japan

2. Department of Radiology, St. Marianna University School of Medicine, Japan

3. Department of Radiology, Kurume University School of Medicine, Japan

4. Department of Radiology, Self-Defense Forces Central Hospital, Japan

5. Terumo Medical Pranex, R & D Center, Terumo Corporation, Japan

6. Department of Radiology, Tokai University School of Medicine, Japan

7. Department of Radiology, Mie University School of Medicine, Japan

8. Department of Diagnostic Radiology, Keio University School of Medicine, Japan

9. Department of Radiology, Narumi Hospital, Japan

10. Department of Radiology, Hyogo College of Medicine, Japan

11. Department of Radiology, Daito Central Hospital, Japan

Abstract

Purpose. To evaluate the educational effect of the Japanese Society of Interventional Radiology 7th Academic Summer Seminar from a technical perspective.Materials and Methods. Nineteen trainees participated in the seminar. The seminar consisted of vertebroplasty trainings using swine with the single-plane landmark method and with the ISOcenter Puncture (ISOP) method. All trainees were advised by an instructor as they operated the instruments and punctured the vertebra. For each trainee, the accuracy in the final position of the needle tip of the initial puncture in each swine training was evaluated.Results. Error in the final position of the needle tip of ≥5 mm from the target puncture site occurred in the lateral direction in 42% (8/19) of trainees with the landmark method and 5% (1/19) with the ISOP method. No error ≥5 mm occurred in the vertical or anteroposterior directions. In terms of puncture accuracy, error in the lateral direction was significantly lower with the ISOP method than with the landmark method (2.2 ± 1.5 mm versus 5.6 ± 3.2 mm).Conclusion. This seminar was effective training for trocar placement for beginners. The puncture was more accurate with the ISOP method than with the landmark method.

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3