Correlation between Doppler, Manual Morphometry, and Histopathology Based Morphometry of Radial Artery as a Conduit in Coronary Artery Bypass Grafting

Author:

Yadava Om Prakash1,Sharma Vinod2,Prakash Arvind3,Ahlawat Vikas1,Kundu Anirban1ORCID,Mohanty Bikram K.1,Mishra Rekha2,Dinda Amit K.4

Affiliation:

1. Department of Cardiothoracic Surgery, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, India

2. Department of Cardiology, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, India

3. Department of Cardiac Anesthesiology, National Heart Institute, 49-50 Community Centre, East of Kailash, New Delhi 110065, India

4. Department of Pathology, All India Institute of Medical Sciences, New Delhi 110029, India

Abstract

Background. Long-term graft patency is the major factor impacting survival after coronary artery bypass grafting. Arteries are superior in this regard. Radial artery is considered the second best conduit after internal mammary artery. Several studies have shown excellent radial artery patency. We evaluated the morphologic characteristics of radial artery by three modalities, (i) preoperative Doppler ultrasound, (ii) intraoperative manual morphometry, and (iii) postoperative histology-based morphometry, and compared these with the aim of validating Doppler as a noninvasive test of choice for preoperative assessment of radial artery.Methods. This was a prospective study involving 100 patients undergoing coronary artery bypass grafting in which radial artery was used. The radial artery was assessed using preoperative Doppler ultrasound studies, intraoperative morphometry, and postoperative histopathology and morphometry. The morphometric measurements included (i) luminal diameter, (ii) intimal and medial thickness, and (iii) intima-media thickness ratio.Results. Using Bland-Altman plots, there was a 95% limit of agreement between the preoperative Doppler measurements and the postoperative histopathology and morphometry.Conclusion. Doppler ultrasound is an accurate screening test for evaluation of radial artery, in terms of intimal/medial thickness and luminal diameter as a conduit in coronary artery bypass grafting and has been validated by both morphometric and histopathology based studies.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3