An Experimental Intervention Study Assessing the Impact of a Thin Silicone Gel Surface Overlay on Interface Pressure

Author:

Angmorterh Seth Kwadjo1ORCID,England Andrew2,Aboagye Sonia3,Ofori Eric Kwasi1,Hogg Peter4

Affiliation:

1. Department of Medical Imaging, School of Allied Health Sciences, University of Health and Allied Sciences (UHAS), Ho, Ghana

2. School of Allied Health Professions, Keele University, Staffordshire, Newcastle, UK

3. Department of Speech, Language & Hearing Sciences, School of Allied Health Sciences, University of Health and Allied Sciences (UHAS), Ho, Ghana

4. Directorate of Radiography, School of Healthcare Sciences, Allerton Building, University of Salford, Salford—Greater Manchester, UK

Abstract

Introduction. The incidence of pressure ulcers (PUs) presents a substantial threat to patients, especially geriatric patients, those with restricted mobility, and patients suffering from chronic diseases such as cancer. PUs creates a huge financial burden on healthcare authorities and patients, costing billions to treat and manage. Radiography and radiotherapy patients may experience medical device related (MDR) PUs and studies have shown that high interface pressure (IP) values exist for the head when placed on an X-ray table without a mattress. These high IP values pose a PU risk to patients, especially those accessing prolonged radiography/radiology and radiotherapy procedures. The current study assessed the impact on IP values for the head from using a thin silicone gel surface overlay during radiographic procedures and identified whether this reduced the risk of PUs. Materials and Methods. A calibrated XSENSOR pressure mat was used to measure IP for the head on an X-ray table with and without a thin silicone gel surface overlay. Prior to pressure mapping, the silicone gel surface overlay was assessed for its impact on radiation attenuation and image quality. Results. Study participants were 14 males (70%) and six females (30%), with an age range of 25–53 years (mean = 34.4 ± 7.0). Paired-samples t-test results indicated that there was a statistically significant decrease in the mean IP for the head on the X-ray table without the silicone gel surface overlay (mean = 83.9 ± 8.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 62.4 ± 6.1 in mmHg),p0.001. Paired-samples t-test results indicated that there was a statistically significant decrease in the mean peak pressure index (PPI) for the head on the X-ray table without the silicone gel surface overlay (mean = 205.1 ± 28.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 159.8 ± 26.8 in mmHg),p0.001. Conclusions. The use of a thin silicone gel surface overlay could reduce IP risk for the head by approximately 25%. The reduction in IP risk could have a significant impact in reducing the risk of developing a PU. To ensure maximum benefit, the silicone gel surface overlay should be evaluated to address the specific needs within radiography and radiotherapy planning and treatment settings.

Funder

Ghana Education Trust Fund

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3