Effectiveness of Charcoal Adsorbent in Flue Gas Filters for PCB Reduction in Smoke from Hospital Incinerators

Author:

Adu Robert Ohene1ORCID,Gyasi Samuel Fosu23ORCID,Essumang David Kofi4ORCID

Affiliation:

1. Department of Civil and Environmental Engineering, University of Energy and Natural Resources, Sunyani, BA, Ghana

2. Department of Biological Science, University of Energy and Natural Resources, Sunyani, BA, Ghana

3. Center for Research in Applied Biology, CeRAB, University of Energy and Natural Resources, Sunyani, BA, Ghana

4. Department of Chemistry, School of Physical Sciences, College of Agriculture and Natural Sciences, University of Cape Coast, Cape Coast, Ghana

Abstract

The release of gas-phase polychlorinated biphenyls (PCBs) as one of the persistent organic pollutants (POPs) is an unfortunate result of combustion, especially from medical waste incinerators. This tends to make incinerators unpopular. The idea of a cheaply available air pollution control device fitted to incinerator chimneys can justify the continued use of incinerators. A gas filter unit, consisting of 3 filter beds with activated charcoal as an adsorbent, was designed, constructed, and fitted onto an existing incinerator at a university hospital in Ghana. Flue gas from the incinerator was sampled before and after the filter beds, using cylindrically-shaped mini-polyurethane foam (mini-PUF) samplers, and the analytes in the samples were then Soxhlet-extracted, purified, and analyzed for certain PCBs using the gas chromatography-mass spectrometer (GC-MS) technique. Twelve of the 14 indicators PCBs analyzed in the smoke samples were present, and 11 of them saw mean reductions ranging from 3.67% to 54.9% by the charcoal filter beds. These were PCB 18, PCB 28, PCB 31, PCB 44, PCB 101, PCB 118, PCB 138, PCB149, PCB 153, PCB 170, and PCB180. The gaseous concentrations of PCBs before filtration ranged from 0.0000788 ng/m3 for PCB 180 to 0.00129 ng/m3 for PCB 153. After the filtration by the charcoal adsorbent, they ranged from 0.00003734 ng/m3 for PCB 170 to 0.00112016 ng/m3 for PCB 153. The highest mean reduction of 54.9% came from the homologue, PCB 180, whilst the homologue with a dioxin-like character (PCB 118) saw a 22.44% reduction. This suggests that dioxins and other dioxin-like compounds are most likely adsorbed by the charcoal adsorbent. This gas filter unit should further be investigated for its effectiveness at removing other dioxin-like PCBs, dioxins, and furanes and for testing the effectiveness of thermophilic bacterial strains that can further metabolize these POPs into less harmful products.

Publisher

Hindawi Limited

Subject

Energy Engineering and Power Technology,Condensed Matter Physics,Fuel Technology,General Chemical Engineering

Reference23 articles.

1. Air pollution killed nearly half a million newborns in 2019, report finds;D. Welle,2020

2. aAir pollution killing more people in Ghana;M. Chasant,2019

3. Source characterization and risk of exposure to atmospheric polychlorinated biphenyls (PCBs) in Ghana

4. Best Environmental Practices And Alternative Technologies For Medical Waste Management;J. Emmanuel,2007

5. Health care waste management in Ghana;MOH,2006

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3