Accelerated 19F·MRI Detection of Matrix Metalloproteinase-2/-9 through Responsive Deactivation of Paramagnetic Relaxation Enhancement

Author:

Faas Henryk M.12ORCID,Krupa James L.3ORCID,Taylor Alexander J.12ORCID,Zamberlan Francesco3ORCID,Philp Christopher J.14,Williams Huw E. L.3,Johnson Simon R.4,Pavlovskaya Galina E.14,Thomas Neil R.3ORCID,Meersmann Thomas145ORCID

Affiliation:

1. Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham NG7 2RD, UK

2. Division of Clinical Neuroscience, School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK

3. Centre for Biomolecular Sciences, School of Chemistry, University of Nottingham, Nottingham NG7 2RD, UK

4. Respiratory Medicine and Biomedical Research Centre, School of Medicine, University of Nottingham, Nottingham NG7 2UH, UK

5. Department of Electrical and Electronic Engineering, University of Nottingham, Ningbo 315100, China

Abstract

Paramagnetic gadolinium ions (GdIII), complexed within DOTA-based chelates, have become useful tools to increase the magnetic resonance imaging (MRI) contrast in tissues of interest. Recently, “on/off” probes serving as 19F·MRI biosensors for target enzymes have emerged that utilize the increase in transverse (T2 or T2) relaxation times upon cleavage of the paramagnetic GdIII centre. Molecular 19F·MRI has the advantage of high specificity due to the lack of background signal but suffers from low signal intensity that leads to low spatial resolution and long recording times. In this work, an “on/off” probe concept is introduced that utilizes responsive deactivation of paramagnetic relaxation enhancement (PRE) to generate 19F longitudinal (T1) relaxation contrast for accelerated molecular MRI. The probe concept is applied to matrix metalloproteinases (MMPs), a class of enzymes linked with many inflammatory diseases and cancer that modify bioactive extracellular substrates. The presence of these biomarkers in extracellular space makes MMPs an accessible target for responsive PRE deactivation probes. Responsive PRE deactivation in a 19F biosensor probe, selective for MMP-2 and MMP-9, is shown to enable molecular MRI contrast at significantly reduced experimental times compared to previous methods. PRE deactivation was caused by MMP through cleavage of a protease substrate that served as a linker between the fluorine-containing moiety and a paramagnetic GdIII-bound DOTA complex. Ultrashort echo time (UTE) MRI and, alternatively, short echo times in standard gradient echo (GE) MRI were employed to cope with the fast 19F transverse relaxation of the PRE active probe in its “on-state.” Upon responsive PRE deactivation, the 19F·MRI signal from the “off-state” probe diminished, thereby indicating the presence of the target enzyme through the associated negative MRI contrast. Null point 1H·MRI, obtainable within a short time course, was employed to identify false-positive 19F·MRI responses caused by dilution of the contrast agent.

Funder

Biotechnology and Biological Sciences Research Council

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3