Abstract
Study questionIs there a difference in the number of repetitions in the 1-minute sit-to-stand (1MSTS) test using an individually adapted seat height to 90° knee flexion (1MSTSIND), compared with the commonly used standard chair seat height of 46 cm (1MSTSSTD), in people with COPD?MethodsWe conducted a single-centre, single-blinded, randomised crossover trial in people with COPD between August 2020 and March 2021 at a specialised rehabilitation clinic in Switzerland. After a learning 1MSTS test, all participants performed two 1MSTS tests in random order on consecutive days. Participants were blinded, as they did not receive detailed information on the testing protocols.Results49 individuals with COPD (47% female) participated. In a regression model adjusted for sequence period and subject, 1MSTS test performance was lower on 1MSTSIND compared to 1MSTSSTD (−0.78 repetitions, 95% CI −1.47 to −0.11). In a second regression model additionally including the knee angle and an interaction term (1MSTSIND×knee angle), the interaction term was significant: 0.18 (95% CI 0.05 to 0.30). The limits of agreement were between −5.5 and 4 repetitions.ConclusionAlthough we observed a statistically significant difference between 1MSTSIND and 1MSTSSTD on a population level, the difference is negligible. Further studies may be needed to determine whether individual adaptation of seat height is needed for very tall or short people to ensure a valid assessment of 1MSTS test performance in COPD.
Publisher
European Respiratory Society (ERS)
Subject
Pulmonary and Respiratory Medicine
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献