Optimization of a methodology for simultaneous determination of four antidepressants present in fresh water by high efficiency liquid chromatography

Author:

Evagelista Patrícia AlexandreORCID,Vilca Franz ZirenaORCID,Pimpinato Rodrigo FlorianoORCID,Tornisielo Valdemar LuizORCID

Abstract

The occurrence of emerging contaminants is a growing concern in the environmental scenario due to their potential risks to ecosystems. The technologies employed in the treatment of sewage in Brazil are not efficient in removing micropollutants, especially persistent ones. Antidepressants (a class of drugs belonging to emerging contaminants) can reach the environment through the disposal of domestic and industrial effluents. These substances were detected in studies with surface waters, being able to cause changes and accumulate in aquatic organisms. The occurrence and impacts of this class of pollutant are still poorly studied in the country. Thus, there is a need to carry out environmental monitoring. To meet such a goal, scientific advances must be developed, especially those related to the development of analytical skills, equipment, and methods with the necessary sensitivity to research in the different sources of contamination. Accordingly, with the development of analytical techniques, it is possible to determine antidepressant drugs in environmental and / or biological matrices in increasingly small concentrations. Consequently, optimization of current techniques and proposing new ones are crucial before any other actions. The aim of this study was to validate a rapid methodology for determining the presence of four antidepressants - fluoxetine, citalopram, venlafaxine, and sertraline - in fresh water through high performance liquid chromatography. The method involved solid-phase extraction (SPE) with C18 cartridge and quantification by high performance liquid chromatography coupled to a diode array detector with C8 column. No chromatographic interference was observed in the retention time of the antidepressants in this study at the selected wavelength of 235 nm. The study matrix did not interfere in the analyses. Linearity was adequate for the range from 0.5 to 10 µg mL-1, with limits of detection and quantification of 0.03 to 0.09 µg mL-1 and 0.10 to 0.27 µg mL-1 respectively. Accuracy was assessed by testing sample fortification at three concentration levels and estimated by relative standard deviation (RSD). RSD values below 15% were obtained. The recovery interval ranged from 49 to 102%. The analytical method was validated and considered satisfactory for the simultaneous determination of antidepressants in freshwater samples using a C8 column.

Publisher

Universidad Federal de Santa Maria

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Presence and ecotoxicity of residual antidepressants in environmental samples;Environmental Nanotechnology, Monitoring & Management;2023-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3