Accuracy of Roche SARS-CoV-2 Rapid Antigen Test in Nasopharyngeal Swab: Clinical Impression Matters

Author:

Pyar Khin Phyu,Su Khine Khine,Wunna Kyaw,Thant Myo,Myat Kaung,Aung Aung,Htet Aung Zar Ni,Maung Nyan Lin,Kyaw Aung Phyoe,Zaw Oo Min Lynn,Tun Kyaw Zwa,Ko Aung Kyaw Ko,Thu Kyaw,Tun Thein Soe,Oo Nyan Ye,Latt Chan Nyein,Tun Thi Han,Myint Si Thu,Oo Aung Phyo,Ko Min Win Ko,Win Kyaw Khine,Yan Hein Wai,Oo Thet Mg,Tin Win Myint

Abstract

Background: In COVID-19 pandemic, the diagnosis and treatment must be as early as possible to save the life of each patient. Moreover, screening of asymptomatic carriers, close contacts or healthy subjects must not be delay to prevent transmission to publics. For confirmation of diagnosis of SARS-CoV-2 infection, nasopharyngeal swab must be tested either by real-time Reverse Transcription Polymerase Chain Reaction (RT-PCR) tests or Rapid Antigen Test (RAT). RAT is faster, easier and cheaper; thus, it is suitable for health service in developing country. Objectives: The aim of this study was to assess the diagnostic accuracy of Roche SARS-CoV-2 Rapid Antigen Test (RAT) in diagnosing SARS-CoV-2 infection. Methods: Hospital based exploratory study was done in out-patient department and fever clinic, and molecular laboratory of No. (1) Defence Services General Hospital. Nasopharyngeal swabs were taken, and the Roche SARS- CoV-2 RAT was conducted in parallel with RT-PCR test (reference standard). Results: Among the 932 patients/subjects recruited, RT-PCR was positive in 468 individuals, corresponding to a prevalence of 50.2%. The RAT was positive in 363 patients (60.4%), false positive in 120 patients; it was negative in 569 individuals (39.6%), false negative in 225 patients. The overall sensitivity of the RAT was 51.9% (95% Confidence Interval [CI] 47.29-56.53) and, the specificity was 74.1% (95% CI 69.9-78.07); positive predictive value was 66.9% and negative predictive value was 60.5%. The sensitivity varied with Ct value; 78% in clinical samples with Ct values < 20, 57.5% in those with Ct values between 21 and 25, 41.8% in samples with Ct values between 26 and 30, and, 36.4% in samples with Ct value > 30. Conclusion: The accuracy of the SARS-CoV-2 Roche RAT in diagnosing SARS-CoV-2 infections was inferior to RT-PCR and manufacturer’s data. The sensitivity was with low Cycle threshold values < 20 which were inversely related to the viral load. RAT test should be used in association with clinical impression of physicians. In hospital setting especially in emergency department, the role of RAT should be reconsidered in those patients presenting with anosmia and some cases of dyspnoea, late symptoms in the course of disease, as the RAT results would be false negative. Other errors may arise if the operator for RAT has to handle more than recommended tests per hour especially in the peak of epidemics.

Publisher

SciRes Literature LLC

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3