Extremity Exposure with 99mTc - Labelled Radiopharmaceuticals in Diagnostic Nuclear Medicine

Author:

Nyathi Mpumelelo1ORCID,Moeng Thabiso Maria1,Maboe Doctor Paul A1

Affiliation:

1. Department of Medical Physics, School of Medicine, Sefako Makgatho Health Sciences University, Ga-Rankuwa, Pretoria, South Africa

Abstract

Background: Extremity exposures may raise the risk of cancer induction among radiographers involved in the preparation and administration of technetium-99m labelled radiopharmaceuticals. Objective: To estimate finger doses on radiographers at a South African tertiary hospital. Methods: Adhesive tape was used to securely fix a calibrated thermoluminescent dosimeter (TLD) on fingertips and bases of ring and index fingers of both hands of five radiographers who prepared and administered technetium-99m labelled radiopharmaceuticals. Rubber gloves were worn to avoid TLD contamination. TLDs doses were read with a Harsaw TLD Reader (Model 3500) after a week. Results: Five radiographers prepared and administered technitium-99m labelled radiopharmaceuticals (activity range; 78.20 GBq - 132.78 GBq during a one-week measurement period). A radiographer handling 132.78 GBq received 4.74±0.52 mSv on both hands; 5.52, 4.55, 5.11 and 4.60 mSv on the fingertip of the index finger of the dominant hand (FIDH), fingertip of the ring finger of the dominant hand (FRDH), fingertip of the index finger of the non-dominant hand (FINDH) and fingertip of the ring finger of the non-dominant hand (FRNDH), respectively. The respective doses received on the finger bases were 4.50 mSv, 4.60, 4.21 and 3.48 mSv. The radiographer handling 78.20 GBq received 0.85±0.18 mSv on both hands, 1.04, 1.17, 0.77 and 1 mSv for the FIDH, FRDH, FINDH and FRNDH, respectively, while respective doses for the bases were 0.8, 0.9, 0.6 and 0.8 mSv. Conclusion: The extremity exposures were below the annual limit (500 mSv). However, the use of syringe shields could still reduce the finger doses further.

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmacology,Radiology Nuclear Medicine and imaging

Reference26 articles.

1. Yonekura Y.; Mattsson S.; Flux G.; Bolch W.T.; Fisher D.R.; Lassman M.; Doruff M.; Divgi C.; Zanzonico P.; ICRP Publication 140: Radiological Protection in Therapy with Radiopharmaceuticals 2019

2. Mettler F.A.; Guiberteau M.J.; Essentials of the Nuclear Medicine Imaging 2006

3. Payolla F.B.; Massabni A.C.; Orvig C.; Radiopharmaceuticals for diagnosis in nuclear medicine: a short review Eclética Química Journal 2019,44(3),11-19

4. Gano L.; Paulo A.; Conventional Nuclear Medicine Radiopharmaceuticals

5. Cherry S.R.; Sorenson J.A.; Phelps M.E.; Physics of Nuclear Medicine 2012

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3